A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Novel Geometries for Stereotactic Localizers. | LitMetric

Novel Geometries for Stereotactic Localizers.

Cureus

Principal Engineer, Retired, Palo Alto, USA.

Published: June 2021

Introduction: The N-localizer is generally utilized in a 3-panel or, more rarely, a 4-panel system for computing stereotactic positions. However, a stereotactic frame that incorporates a 2-panel (bipanel) N-localizer system with panels affixed to only the left and right sides of the frame offers several advantages: improved ergonomics to attach the panels, reduced claustrophobia for the patient, mitigation of posterior panel contact with imaging systems, and reduced complexity. A bipanel system that comprises two standard N-localizer panels yields only two three-dimensional (3D) coordinates, which are insufficient to solve for the stereotactic matrix without further information. While additional information to determine the stereotactic positions could include scalar distances from Digital Imaging and Communications in Medicine (DICOM) metadata or 3D regression across the imaging volume, both have risks related to noise and error propagation. Therefore, we sought to develop new stereotactic localizers that comprise only lateral fiducials (bipanel) that leave the front and back regions of the patient accessible but that contain enough information to solve for the stereotactic matrix using each image independently.  Methods: To solve the stereotactic matrix, we assumed the need to compute three or more 3D points from a single image. Several localizer options were studied using Monte Carlo simulations to understand the effect of errors on the computed target location. The simulations included millions of possible combinations for computing the stereotactic matrix in the presence of random errors of 1mm magnitude. The matrix then transformed coordinates for a target that was placed 50mm anterior, 50mm posterior, 50mm lateral, or 50mm anterior and 50mm lateral to the centre of the image. Simulated cross-sectional axial images of the novel localizer systems were created and converted into DICOM images representing computed tomography (CT) images.  Results: Three novel models include the M-localizer, F-localizer, and Z-localizer. For each of these localizer systems, optimized results were obtained using an overdetermined system of equations made possible by more than three diagonal bars. In each case, the diagonal bar position was computed using standard N-localizer mathematics. Additionally, the M-localizer allowed adding a computation using the Sturm-Pastyr method. Monte Carlo simulation demonstrated that the Z-localizer provided optimal results.

Conclusion: The three proposed novel models meet our design objectives. Of the three, the Z-localizer produced the least propagation of error. The M-localizer was simpler and had slightly more error than the Z-localizer. The F-localizer produced more error than either the Z-localizer or M-localizer. Further study is needed to determine optimizations using these novel models.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8275055PMC
http://dx.doi.org/10.7759/cureus.15620DOI Listing

Publication Analysis

Top Keywords

stereotactic matrix
16
solve stereotactic
12
novel models
12
stereotactic
9
stereotactic localizers
8
computing stereotactic
8
stereotactic positions
8
standard n-localizer
8
monte carlo
8
50mm anterior
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!