Background: Volumetric capnography is increasingly being applied in cardiopulmonary resuscitation. However, during cardiopulmonary resuscitation, the abnormal ventilation state affects the monitoring effect of the most commonly used capnography-derived parameter, the partial carbon dioxide end-tidal pressure (PetCO). In this study, we evaluated the ability of a new volumetric capnography-derived parameter, the ratio between the PetCO and the volume of carbon dioxide (CO) eliminated per min and per kilogram of body weight, for detecting hyperventilation during cardiopulmonary resuscitation.

Methods: We used 12 porcine models of primary ventricular fibrillation-induced cardiac arrest. Ventricular fibrillation was induced and left untreated for 4 min. Standardized chest compressions were performed throughout the experiment using mechanical cardiopulmonary resuscitation. Following 5 min of normal ventilation as a washout period, each animal underwent 4 types of ventilation. The main outcome measures were the PetCO, the ratio between the PetCO and the volume of CO eliminated per min and per kilogram of body weight with each ventilation type.

Results: Different ventilation types had a significant effect on the volumetric capnography-derived parameters. The PetCO and ratio between the PetCO and the volume of CO eliminated per min and per kilogram of body weight values during cardiopulmonary resuscitation was significantly higher in non-hyperventilating than in hyperventilating animals. The ratio reflected hyperventilation accurately and immediately, with an area under the curve (AUC) of 0.98. The optimal cut-off point of the ratio for discriminating hyperventilation from non-hyperventilation was 6.36, with a sensitivity and specificity of 0.99 and 0.89, respectively.

Conclusions: The ratio between the PetCO and the volume of CO eliminated per min and per kilogram of body weight showed good performance in discriminating hyperventilation from non-hyperventilation and was sensitive to changes in ventilation status. This ratio may be a valuable clinical indicator for monitoring the ventilation status during cardiopulmonary resuscitation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8264707PMC
http://dx.doi.org/10.21037/jtd-21-50DOI Listing

Publication Analysis

Top Keywords

cardiopulmonary resuscitation
24
ratio petco
16
petco volume
16
eliminated min
16
min kilogram
16
kilogram body
16
body weight
16
volumetric capnography-derived
12
capnography-derived parameter
12
volume eliminated
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!