A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

High-resolution achromatic X-ray optical systems for broad-band imaging and for focusing attosecond pulses. | LitMetric

High-resolution achromatic X-ray optical systems for broad-band imaging and for focusing attosecond pulses.

Proc Math Phys Eng Sci

Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany.

Published: July 2021

Achromatic focusing systems for hard X-rays are examined which consist of a refractive lens paired with a diffractive lens. Compared with previous analyses, we take into account the behaviour of thick refractive lenses, such as compound refractive lenses and waveguide gradient index refractive lenses, in which both the focal length and the position of the principal planes vary with wavelength. Achromatic systems formed by the combination of such a thick refractive lens with a multilayer Laue lens are found that can operate at a focusing resolution of about 3 nm, over a relative bandwidth of about 1%. With the appropriate distance between the refractive and diffractive lenses, apochromatic systems can also be found, which operate over relative bandwidth greater than 10%. These systems can be used to focus short pulses without distorting them in time by more than several attoseconds. Such systems are suitable for high-flux scanning microscopy and for creating high intensities from attosecond X-ray pulses.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8277474PMC
http://dx.doi.org/10.1098/rspa.2021.0334DOI Listing

Publication Analysis

Top Keywords

refractive lenses
12
refractive lens
8
thick refractive
8
relative bandwidth
8
systems
6
refractive
6
high-resolution achromatic
4
achromatic x-ray
4
x-ray optical
4
optical systems
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!