Background: The Reflux Band, an external upper esophageal sphincter (UES) compression device, reduces esophago-pharyngeal reflux events. This study aimed to assess device efficacy as an adjunct to proton pump inhibitor (PPI) therapy in patients with laryngopharyngeal reflux (LPR).
Methods: This two-phase prospective clinical trial enrolled adults with at least 8 weeks of laryngeal symptoms (sore throat, throat clearing, dysphonia) not using PPI therapy at two tertiary care centers over 26 months. Participants used double dose PPI for 4 weeks in Phase 1 and the external UES compression device nightly along with PPI for 4 weeks in Phase 2. Questionnaire scores and salivary pepsin concentration were measured throughout the study. The primary endpoint of symptom response was defined as reflux symptom index (RSI) score ≤ 13 and/or > 50% reduction in RSI.
Results: Thirty-one participants completed the study: 52% male, mean age 47.9 years (SD 14.0), and mean body mass index (BMI) 26.2 kg/m (5.1). Primary endpoint was met in 11 (35%) participants after Phase 1 (PPI alone) and 17 (55%) after Phase 2 (Device + PPI). Compared to baseline, mean RSI score (24.1 (10.9)) decreased at end of Phase 1 (PPI alone) (21.9 (9.7); p = 0.06) and significantly decreased at end of Phase 2 (Device + PPI) (15.5 (10.3); p < 0.01). Compared to non-responders, responders to Device + PPI had a significantly lower BMI (p = 0.02) and higher salivary pepsin concentration (p = 0.01).
Conclusion: This clinical trial highlights the potential efficacy of the external UES compression device (Reflux Band) as an adjunct to PPI for patients with LPR (ClinicalTrials.Gov NCT03619811).
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8286644 | PMC |
http://dx.doi.org/10.1007/s10620-021-07172-2 | DOI Listing |
Cureus
December 2024
Department of Surgery, Florida Atlantic University Charles E. Schmidt College of Medicine, Boca Raton, USA.
Subtrochanteric fractures in older patients are typically due to low-energy falls. The standard of care is intramedullary nailing. The Smith & Nephew Trigen Intertan (Memphis, TN, US) is an intramedullary nail with a novel design that incorporates two integrated compression screws.
View Article and Find Full Text PDFJ Biomech Eng
January 2025
Department of orthopedics, the Second Affiliated Hospital of Medical College of Zhejiang University, Hangzhou, Zhejiang, 310000, China.
This study aims to compare the sinking and shifting of an enhanced escape-proof intervertebral fusion device with a traditional TLIF intervertebral fusion device.Five specimens each of the improved escape-resistant intervertebral cage and the traditional TLIF cage were selected. Four types of mechanical tests were conducted on each cage, Furthermore, a blade-cutting torque test was performed on the escape-resistant cage, with the recording of load-displacement curves and mechanical values.
View Article and Find Full Text PDFNat Commun
January 2025
Center for High Pressure Science and Technology Advanced Research, Beijing, 100093, China.
Photon emission may be continuously produced from mechanical work through self-recoverable mechanoluminescence (ML). Significant progress has been made in high-performance ML materials in the past decades, but the rate-dependent ML kinetics remains poorly understood. Here, we have conducted systematic studies on the self-recoverable ML of Mn-doped SrZnOS (SrZnOS: Mn) under rapid compression up to ~10 GPa.
View Article and Find Full Text PDFSci Rep
January 2025
Biomedical Engineering Department, Faculty of Engineering, Helwan University, Cairo, Egypt.
Car accidents, infections caused by bacteria or viruses, metastatic lesions, tumors, and malignancies are the most frequent causes of chest wall damage, leading to the removal of the affected area. After excision, artificial bone or synthetic materials are used in chest wall reconstruction to restore the skeletal structure of the chest. Chest implants have traditionally been made from metallic materials like titanium alloys due to their biocompatibility and durability.
View Article and Find Full Text PDFZhong Nan Da Xue Xue Bao Yi Xue Ban
August 2024
Xiangya Stomatological Hospital and Xiangya School of Stomatology, Central South University; Hunan Engineering Research Center for Oral Digital Intelligence and Personalized Medicine; Hunan 3D Printing Engineering Research Center of Oral Care; WANG Songling Academician Workstation for Oral-maxilofacial and Regenerative Medicine, Central South University, Changsha 410078.
Objectives: Drug-loaded mucoadhesive silk fibroin (SF) microneedle patch can overcome the limitations of low bioavailability and significant pain associated with traditional treatment methods, such as topical application or injection of triamcinolone for oral submucous fibrosis (OSF). However, these systems release the drug too quickly, failing to meet the clinical requirements. This study aims to construct a mucoadhesive SF microneedle patch pre-assembled with silk fibroin nanospheres (SFN) and explore its ability to sustain the release of triamcinolone in the treatment of OSF.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!