A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Characterization of the cylindrical electrospun nanofibrous polysulfone membrane for hemodialysis with modelling approach. | LitMetric

Characterization of the cylindrical electrospun nanofibrous polysulfone membrane for hemodialysis with modelling approach.

Med Biol Eng Comput

Genetic and Environmental Adventures Research Center, school of Abarkouh Paramedicine, Shahid Sadoughi University of Medical Sciences, Yazd, Iran.

Published: August 2021

Electrospun nanofibrous membrane (ENM) is a membrane fabricated using electrospinning technique which has considerable characteristics such as high porosity, nanometer pore size, and simple process. Although ENMs are being evaluated in various medical applications, the effectiveness for hemodialysis (HD) has not been evaluated carefully. Thus, in this study, the cylindrical electrospun nanofibrous polysulfone (CENP) membrane was fabricated and its performance in the dialysis adequacy in HD patients was evaluated.The CENP membrane was fabricated in a tabular shape. The physical characteristics of the membrane are examined using scanning electron microscope (SEM) images and the permporometry technique. Then, its efficiency in urea and creatinine removal from the blood serum of 21 HD patients was evaluated at a low blood flow rate (BFR) of 200 ml min and dialysate fluid rate (DFR) of 300 ml min. Afterwards, the results were modeled and optimized using artificial neural network (ANN) and genetic algorithm (GA), respectively. Finally, sensitive analysis was performed via Spearman's rank correlation coefficient. The highest dialysis adequacy was observed in membranes with an inner diameter of 3 mm. The CENP membrane belongs to the super high-flux membrane and it could be replaced with existing commercial hollow fiber membranes.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11517-021-02404-zDOI Listing

Publication Analysis

Top Keywords

electrospun nanofibrous
12
membrane fabricated
12
cenp membrane
12
cylindrical electrospun
8
nanofibrous polysulfone
8
membrane
8
dialysis adequacy
8
characterization cylindrical
4
polysulfone membrane
4
membrane hemodialysis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!