A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Performance of the Diasorin SARS-CoV-2 antigen detection assay on the LIAISON XL. | LitMetric

Background: The current reference standard to diagnose a SARS-CoV-2 infection is real-time reverse transcriptase polymerase chain reaction (RT-PCR). This test poses substantial challenges for large-scale community testing, especially with respect to the long turnaround times. SARS-CoV-2 antigen tests are an alternative, but typically use a lateral flow assay format rendering them less suitable for analysis of large numbers of samples.

Methods: We conducted an evaluation of the Diasorin SARS-CoV-2 antigen detection assay (DAA) compared to real-time RT-PCR (Abbott). The study was performed on 248 (74 qRT-PCR positive, 174 qRT-PCR negative) clinical combined oro-nasopharyngeal samples of individuals with COVID-19-like symptoms obtained at a Municipal Health Service test centre. In addition, we evaluated the analytical performance of DAA with a 10-fold dilution series of SARS-CoV-2 containing culture supernatant and compared it with the lateral flow assay SARS-CoV-2 Roche/SD Biosensor Rapid Antigen test (RRA).

Results: The DAA had an overall specificity of 100% (95%CI 97.9%-100%) and sensitivity of 73% (95%CI 61.3%-82.7%) for the clinical samples. Sensitivity was 86% (CI95% 74.6%-93.3%) for samples with Ct-value below 30. Both the DAA and RRA detected SARS-CoV-2 up to a dilution containing 5.2 × 10 fifty-percent-tissue-culture-infective-dose (TCID50)/ml.

Discussion: The DAA performed adequately for clinical samples with a Ct-value below 30. Test performance may be further optimised by lowering the relative light unit (RLU) threshold for positivity assuming the in this study used pre-analytical protocol . The test has potential for use as a diagnostic assay for symptomatic community-dwelling individuals early after disease onset in the context of disease control.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8264273PMC
http://dx.doi.org/10.1016/j.jcv.2021.104909DOI Listing

Publication Analysis

Top Keywords

sars-cov-2 antigen
12
diasorin sars-cov-2
8
antigen detection
8
detection assay
8
lateral flow
8
flow assay
8
clinical samples
8
samples ct-value
8
sars-cov-2
7
assay
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!