A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An isotope dilution liquid chromatography-mass spectrometry method for detection of melamine in milk powder. | LitMetric

An isotope dilution liquid chromatography-mass spectrometry method for detection of melamine in milk powder.

Food Addit Contam Part A Chem Anal Control Expo Risk Assess

Life Sciences Division, Sri Lanka Atomic Energy Board, Colombo, Sri Lanka.

Published: November 2021

Adulteration/unintentional contamination of milk with melamine could have negative health and economic implications especially in the developing countries due to insufficient laboratory support and surveillance. This paper presents an Isotope Dilution Liquid Chromatography-Mass Spectrometry (ID LC-MS) method developed for detection of melamine in powdered milk. The rapid sample preparation involved dissolution of 1g of milk powder in 2.5% formic acid, precipitation of protein with acetonitrile, spiking of samples with melamine (triamine-N) at 200 µg L and detection of intrinsic N-melamine molecular ratio to the spike. The isotope dilution calibration procedure was free from matrix effects, unlike other methods where the detector sensitivity can fluctuate up to several orders of magnitude. Limit of detection of the method was 13 µg kg, and the recovery of melamine at 50, 100, and 250 µg kg was 78.7-126.3%. The method was used to determine melamine levels in 22 milk powder products (local and imported) available in Sri Lanka. Melamine was detected in all the samples (range = 0.33-0.96 mg kg). Full cream milk powders (both local and imported) contained melamine in the range of 0.39-0.84 mg kg, and various health and pregnancy formulas contained <0.5 mg kg of melamine. Two imported infant formula samples contained the highest levels of melamine (0.96 and 0.94 mg kg). Although these melamine levels are below the regulatory limit in Sri Lanka (1 mg kg), a monitoring programme would ensure consumer safety.

Download full-text PDF

Source
http://dx.doi.org/10.1080/19440049.2021.1937709DOI Listing

Publication Analysis

Top Keywords

isotope dilution
12
milk powder
12
dilution liquid
8
liquid chromatography-mass
8
chromatography-mass spectrometry
8
melamine
8
detection melamine
8
local imported
8
milk
6
method
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!