A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of efficacy of two different doses of tranexamic acid in prevention of post operative blood loss in patients with congenital cyanotic heart disease undergoing cardiac surgery. | LitMetric

Background: The optimal dose of tranexamic acid in minimizing perioperative bleeding is uncertain. We compared efficacy of two different doses of tranexamic acid in reducing post-operative blood loss and its side effects in patients with congenital cyanotic heart disease undergoing cardiac surgery.

Settings And Design: Prospective observational study at a pediatric cardiac center in South India.

Methods: Consecutive cyanotic patients undergoing cardiac surgery were divided into groups I and II to receive either 10 mg/kg or 25 mg/kg of tranexamic acid administered as triple dose regime after induction, during cardiopulmonary bypass, and after protamine. Post-operative blood loss at 24 hours, blood component utilization, incidence of renal dysfunction and seizures were compared.

Results: Totally, 124 patients were recruited, 62 in each group. The pre-operative variables and cardiopulmonary bypass time were comparable. Patients receiving 25 mg/kg had lower post-operative blood loss compared to patients in lower dose group (8.04 ± 8.89 vs 12.41 ± 19.23 ml/kg/24 hours, P = 0.03). There was no difference in the transfused volume of packed red cells (9.21 ± 7.13 ml/kg vs 12.41 ± 9.23 ml/kg, P = 0.712), fresh frozen plasma (13.91 ± 13.38 ml/kg vs 11.02 ± 8.04 ml/kg, P = 0.19), platelets (9.03 ± 6.76 ml/kg vs 10.90 ± 6.9 ml/kg, P = 0.14) or cryoprecipitate (0.66 ± 0.59 ml/kg vs 0.53 ± 0.54 ml/kg, P = 0.5) in group II and I, respectively. Two patients developed renal dysfunction secondary to low cardiac output in lower dose group. There were no seizures.

Conclusions: Tranexamic acid administered at a dose of 25 mg/kg as triple dose regime is associated with lower post-operative blood loss compared to a lower dose of 10 mg/kg in cyanotic patients undergoing cardiac surgery without causing major adverse effects.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8404605PMC
http://dx.doi.org/10.4103/aca.ACA_162_20DOI Listing

Publication Analysis

Top Keywords

tranexamic acid
20
blood loss
20
undergoing cardiac
16
post-operative blood
16
cardiac surgery
12
lower dose
12
efficacy doses
8
doses tranexamic
8
patients
8
patients congenital
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!