A distributed refractive index (RI) sensor based on high-performance optical frequency domain reflectometry was developed by bending a piece of standard single-mode fiber to excite sets of higher-order modes that penetrate the surrounding medium. External variations in RI modifies the profiles of the sets of excited higher-order modes, which are then partially coupled back into the fiber core and interfere with the fundamental mode. Accordingly, the fundamental mode carries the outer varied RI information, and RI sensing can be achieved by monitoring the wavelength shift of the local Rayleigh backscattered spectra. In the experiment, an RI sensitivity of 39.08 nm/RIU was achieved by bending a single-mode fiber to a radius of 4 mm. Additionally, the proposed sensor maintains its buffer coating intact, which boosts its practicability and application adaptability.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.430637DOI Listing

Publication Analysis

Top Keywords

distributed refractive
8
single-mode fiber
8
higher-order modes
8
fundamental mode
8
refractive sensing
4
sensing based
4
based bending-induced
4
bending-induced multimodal
4
multimodal interference
4
interference rayleigh
4

Similar Publications

Purpose: To use swept-source optical coherence tomography angiography (SS-OCTA) to investigate the alterations in retinal vascular density (VD) in patients presenting with congenital unilateral trochlear nerve palsy.

Methods: The medical records of patients diagnosed with congenital unilateral trochlear nerve palsy and those of a healthy control group were reviewed retrospectively. Comprehensive ocular examinations and SS-OCTA imaging were conducted.

View Article and Find Full Text PDF

The aim of this study was to investigate the locational distribution and potential mechanisms of retinal hemorrhages in newborns using fundus photography. A retrospective analysis of 98 consecutive newborns with retinal hemorrhages in at least one eye and 30 control newborns without retinal hemorrhages after uneventful delivery was conducted. Retinal hemorrhages were diagnosed and characterized using fundus photography and indirect ophthalmoscopy.

View Article and Find Full Text PDF

Purpose: To evaluate the incidence, refractive error (RE) association, and distribution of atraumatic rhegmatogenous retinal detachment (RRD) in U.S. military service members (SMs).

View Article and Find Full Text PDF

Achieving a Porous PDMS Film for Passive Cooling through the Utilization of Ultrafine NaCl Sacrificial Templates.

ACS Omega

January 2025

CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Precision Machinery and Instrumentation, University of Science and Technology of China, Hefei, Anhui 230026, P. R. China.

Passive radiative cooling technology serves as an energy-free alternative to traditional cooling systems. Porous polymer structures are frequently employed for radiative cooling by leveraging the refractive index mismatch between the polymer and the pores, enabling the scattering of incoming sunlight. Recently, water-soluble and readily available Sodium chloride (NaCl) particles have been utilized as sacrificial templates for sustainable pore creation.

View Article and Find Full Text PDF

Background: The psychometric properties of the Convergence Insufficiency Symptom Survey (CISS) have been previously determined across the younger adult population. This study investigated the psychometric properties of the CISS in presbyopic adults via classical and Rasch analysis.

Methods: A total of 100 presbyopic individuals (40-60 years) were selected with far and near acuity of 20/20 with their habitual spectacles; 50 had convergence insufficiency and 50 had normal binocular vision.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!