Purpose: Identifying axial length growth rate as an indicator of fast progression before initiating atropine 0.01% for myopia progression in children.
Method: From baseline, axial length growth over six months was measured prospectively. Subjects were then initiated on atropine 0.01% if axial length growth was greater than 0.1mm per 6 months (fast progressors), axial length and spherical equivalent change measurements recorded every six months. The rate of change was compared to the baseline pre-treatment rate. If axial length change was below the threshold, subjects received monitoring only.
Results: 73 subjects were identified as fast progressors and commenced atropine 0.01%, (mean baseline refraction of OD -2.9±1.6, OS -2.9±1.8 and a mean baseline axial length OD 24.62 ± 1.00 mm, OS 24.53 ± 0.99 mm). At six months, the mean paired difference of axial length growth rate was significantly reduced by 50% of baseline (all 73 subjects, p<0.05). 53 subjects followed to 12 months, and 12 to 24 months maintained a reduced growth rate. Change in mean spherical equivalent was significantly reduced compared to pre-treatment refractive error (mean paired difference p<0.05) and at each subsequent visit. 91 children were slow progressors and remained untreated. Their axial length growth rate did not change significantly out to 24 months. Spherical equivalent changed less than -0.5D annually in this group.
Conclusion: Identifying fast progressors before treatment initiation demonstrated a strong treatment effect with atropine 0.01% reducing their individual rate of myopia progression by 50%. Another large group of myopic children, slow progressors, continued without medical intervention. A baseline axial length growth rate is proposed as a guideline to identify fast progressors who are more likely to benefit from atropine 0.01%.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8282033 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0254061 | PLOS |
Pak J Med Sci
January 2025
Sasankoti Mohan Ravi Prakash, DMD, MDS, BDS Dentist and Independent Researcher, Hope Health Inc, 360 N Irby St. Florence, South Carolina, USA 29501.
Background & Objective: Currently, there are many implants in clinical use, making it hard to choose the right one for the patient. The success rate of an implant depends on its diameter, length, and direction of insertion in bone. In implant dentistry, Finite Element Analysis (FEA) simulates intraoral conditions in vitro and analyzes the effects of implant material, diameter, size, and other components related to oral structure on the implant and peri-implant tissues.
View Article and Find Full Text PDFClin Ophthalmol
January 2025
Department of Ophthalmology, Saitama Medical Center, Saitama Medical University, Kawagoe-shi, Saitama, Japan.
Purpose: Among patients with angle-closure glaucoma, it is common to have a short-axial eye, which also makes it difficult to select an appropriate intraocular lens. Previous studies have focused on the ocular biometry of the long-axial eye, whereas only a few reports have focused on the short-axial eye. This study aimed to clarify the characteristics of the short-axial eye on ocular biometry among the elderly Japanese.
View Article and Find Full Text PDFJ Orthop Surg Res
January 2025
Department of Orthopedic Surgery, Affiliated Hospital of Xuzhou Medical University, 99 Huaihai Road, Xuzhou, Jiangsu, 221002, China.
Purpose: To compare the efficacy and safety of skip titanium plates combined with adjacent spinous process suture suspension versus continuous titanium plate fixation in cervical laminoplasty.
Methods: A retrospective analysis of 125 patients (62 men, 63 women, average age 60.9 ± 10.
J AAPOS
January 2025
University of Health Sciences, Department of Ophthalmology, Başakşehir Cam and Sakura City Hospital, Istanbul, Turkey.
Purpose: To use swept-source optical coherence tomography angiography (SS-OCTA) to investigate the alterations in retinal vascular density (VD) in patients presenting with congenital unilateral trochlear nerve palsy.
Methods: The medical records of patients diagnosed with congenital unilateral trochlear nerve palsy and those of a healthy control group were reviewed retrospectively. Comprehensive ocular examinations and SS-OCTA imaging were conducted.
Life (Basel)
January 2025
Institute for Research in Ophthalmology, Foundation for Ophthalmology Development, 61-553 Poznan, Poland.
To compare the accuracy of seven artificial intelligence (AI)-based intraocular lens (IOL) power calculation formulas in medium-long Caucasian eyes regarding the root-mean-square absolute error (RMSAE), the median absolute error (MedAE) and the percentage of eyes with a prediction error (PE) within ±0.5 D. Data on Caucasian patients who underwent uneventful phacoemulsification between May 2018 and September 2023 in MW-Med Eye Center, Krakow, Poland and Kyiv Clinical Ophthalmology Hospital Eye Microsurgery Center, Kyiv, Ukraine were reviewed.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!