To describe the impact of infectious adverse events (IAEs) during ventricular assist device (VAD) support on graft loss, infection, and rejection after pediatric heart transplant (HT). Pedimacs data were linked to Pediatric Heart Transplant Society (PHTS) data for patients receiving a VAD followed by HT between September 2012 and December 2016. Linked patients were categorized into IAE on VAD (group A) and no IAE on VAD (group B). Infectious adverse event locations included nondevice, device (external or internal), and sepsis. Post-HT outcomes for analysis were graft loss, infection, and rejection. Time-dependent analysis included Kaplan-Meier and multiphase parametric hazard function analysis. We linked 207 patients (age 9.4 ± 6.3 years). Post-HT follow-up was 19.4 patient-months (<8 days-4.1 years). Group A included 42 patients (20%) with 62 IAEs. Group B included 165 patients without an IAE. Group A patients were younger (7.4 ± 6.1 vs. 9.5 ± 6.3 years; p = 0.03), waited longer for HT (5.3 ± 4.1 vs. 2.9 ± 2.5 months; p = 0.0005), and were hospitalized longer post-HT (42 ± 59 vs. 23 ± 22 days; p = 0.05). VAD-related IAEs were rare (N = 11). Groups A and B had similar freedom from first post-HT infection, rejection, and graft loss (all p > 0.1). However, patients with VAD-related IAE were somewhat more likely to experience rejection (p = 0.03) and graft loss (p = 0.01). Children with an IAE on VAD who survive to HT are younger, wait longer for HT, and remain hospitalized longer than those without an IAE on VAD. Overall, IAE on VAD did not impact post-HT outcomes, but VAD-related IAE may be associated with graft loss and rejection.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MAT.0000000000001442DOI Listing

Publication Analysis

Top Keywords

iae vad
20
graft loss
16
pediatric heart
12
ventricular assist
8
assist device
8
infectious adverse
8
loss infection
8
infection rejection
8
heart transplant
8
vad group
8

Similar Publications

To describe the impact of infectious adverse events (IAEs) during ventricular assist device (VAD) support on graft loss, infection, and rejection after pediatric heart transplant (HT). Pedimacs data were linked to Pediatric Heart Transplant Society (PHTS) data for patients receiving a VAD followed by HT between September 2012 and December 2016. Linked patients were categorized into IAE on VAD (group A) and no IAE on VAD (group B).

View Article and Find Full Text PDF

Early stage litter decomposition across biomes.

Sci Total Environ

July 2018

Forest & Nature Lab, Department of Forest and Water Management, Ghent University, Geraardsbergsesteenweg 267, 9090 Gontrode, Belgium. Electronic address:

Through litter decomposition enormous amounts of carbon is emitted to the atmosphere. Numerous large-scale decomposition experiments have been conducted focusing on this fundamental soil process in order to understand the controls on the terrestrial carbon transfer to the atmosphere. However, previous studies were mostly based on site-specific litter and methodologies, adding major uncertainty to syntheses, comparisons and meta-analyses across different experiments and sites.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!