Left ventricular hypertrabeculation/noncompaction (LVHT) is associated with arrhythmias. Guidelines for prevention of sudden cardiac death by implanted cardioverter-defibrillator (ICD) also apply to LVHT-patients. Right ventricular perforation by the ICD-lead is a matter of concern. Subcutaneous ICD (S-ICD) may overcome disadvantages of transvenous ICD in patients without a need for pacing therapy. We report a LVHT-patient with arterial hypertension, hyperlipidemia, coronary artery disease with an anterior-wall myocardial infarction 2004 and stroke without neurological deficits in 2018. Since ejection fraction of 33% remained unchanged despite bisoprolol, sacubitril/valsartan and spironolactone, he was treated with S-ICD for primary prevention of sudden cardiac death.

Download full-text PDF

Source
http://dx.doi.org/10.1111/pace.14317DOI Listing

Publication Analysis

Top Keywords

implanted cardioverter-defibrillator
8
coronary artery
8
artery disease
8
prevention sudden
8
sudden cardiac
8
cardiac death
8
subcutaneous implanted
4
cardioverter-defibrillator ventricular
4
ventricular noncompaction
4
noncompaction coronary
4

Similar Publications

Background: Catecholaminergic polymorphic ventricular tachycardia (CPVT) is a rare inherited arrhythmia disorder characterized by ventricular arrhythmia triggered by adrenergic stimulation.

Case Presentation: A 9-year-old boy presented with convulsions following physical exertion. Bidirectional ventricular tachycardia (VT) during a treadmill test led to the diagnosis of catecholaminergic polymorphic ventricular tachycardia (CPVT).

View Article and Find Full Text PDF

Medical and advanced heart failure therapies in Türkiye.

Turk J Med Sci

December 2024

Deputy Health Minister, Ministry of Health, Ankara, Turkiye.

Background/aim: Effective management of heart failure involves evidence-based use of multiple medications and their combinations. Furthermore, dosage escalation of the recommended medications is advised. In cases of advanced heart failure, long-term mechanical assistance devices or heart transplantation surgery may be necessary.

View Article and Find Full Text PDF

Implantable cardioverter defibrillators (ICDs) are implanted in increasing numbers of patients with the aim of treating ventricular arrhythmias in high-risk patients and reducing their risk of dying. Individuals are also living longer with these devices. As a result, a greater number of patients with an ICD will deteriorate either with worsening cardiac failure, another non-cardiac condition or general frailty and will have a limited prognosis.

View Article and Find Full Text PDF

Background: Noninferiority of omitting intraoperative defibrillation threshold (DFT) testing has been documented for transvenous implantable cardioverter defibrillators (ICD) whereas data for the subcutaneous-ICD (S-ICD) regarding the need for DFT testing, especially during S-ICD generator replacement, is not available.

Methods: A total of 112 consecutive patients who underwent S-ICD generator replacement and routine testing were included in this retrospective single-center study and analyzed regarding the outcome of intraoperative DFT.

Results: The majority of patients (87.

View Article and Find Full Text PDF

Background: An atrioventricular defibrillator system with a floating atrial dipole (VDD ICD) can provide atrial sensing by a single lead. Our aim was to compare the arrhythmia detection efficacy of VDD ICDs with conventional single- (VVI) and dual-chamber (DDD) defibrillators.

Methods: Data from consecutive patients undergoing ICD implantation were retrospectively analyzed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!