Left ventricular hypertrabeculation/noncompaction (LVHT) is associated with arrhythmias. Guidelines for prevention of sudden cardiac death by implanted cardioverter-defibrillator (ICD) also apply to LVHT-patients. Right ventricular perforation by the ICD-lead is a matter of concern. Subcutaneous ICD (S-ICD) may overcome disadvantages of transvenous ICD in patients without a need for pacing therapy. We report a LVHT-patient with arterial hypertension, hyperlipidemia, coronary artery disease with an anterior-wall myocardial infarction 2004 and stroke without neurological deficits in 2018. Since ejection fraction of 33% remained unchanged despite bisoprolol, sacubitril/valsartan and spironolactone, he was treated with S-ICD for primary prevention of sudden cardiac death.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/pace.14317 | DOI Listing |
Front Cardiovasc Med
December 2024
Department of Paediatrics and Adolescent Medicine, The University of Hong Kong, Pok Fu Lam, Hong Kong SAR, China.
Background: Catecholaminergic polymorphic ventricular tachycardia (CPVT) is a rare inherited arrhythmia disorder characterized by ventricular arrhythmia triggered by adrenergic stimulation.
Case Presentation: A 9-year-old boy presented with convulsions following physical exertion. Bidirectional ventricular tachycardia (VT) during a treadmill test led to the diagnosis of catecholaminergic polymorphic ventricular tachycardia (CPVT).
Turk J Med Sci
December 2024
Deputy Health Minister, Ministry of Health, Ankara, Turkiye.
Background/aim: Effective management of heart failure involves evidence-based use of multiple medications and their combinations. Furthermore, dosage escalation of the recommended medications is advised. In cases of advanced heart failure, long-term mechanical assistance devices or heart transplantation surgery may be necessary.
View Article and Find Full Text PDFBMJ Support Palliat Care
December 2024
Wolfson Palliative Care Research Centre, University of Hull, Hull, UK.
Implantable cardioverter defibrillators (ICDs) are implanted in increasing numbers of patients with the aim of treating ventricular arrhythmias in high-risk patients and reducing their risk of dying. Individuals are also living longer with these devices. As a result, a greater number of patients with an ICD will deteriorate either with worsening cardiac failure, another non-cardiac condition or general frailty and will have a limited prognosis.
View Article and Find Full Text PDFPacing Clin Electrophysiol
December 2024
Department of Cardiology II - Electrophysiology, University Hospital Münster, Münster, Germany.
Background: Noninferiority of omitting intraoperative defibrillation threshold (DFT) testing has been documented for transvenous implantable cardioverter defibrillators (ICD) whereas data for the subcutaneous-ICD (S-ICD) regarding the need for DFT testing, especially during S-ICD generator replacement, is not available.
Methods: A total of 112 consecutive patients who underwent S-ICD generator replacement and routine testing were included in this retrospective single-center study and analyzed regarding the outcome of intraoperative DFT.
Results: The majority of patients (87.
J Cardiovasc Dev Dis
December 2024
Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, 6725 Szeged, Hungary.
Background: An atrioventricular defibrillator system with a floating atrial dipole (VDD ICD) can provide atrial sensing by a single lead. Our aim was to compare the arrhythmia detection efficacy of VDD ICDs with conventional single- (VVI) and dual-chamber (DDD) defibrillators.
Methods: Data from consecutive patients undergoing ICD implantation were retrospectively analyzed.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!