A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Monte Carlo dose calculation system for ophthalmic brachytherapy based on a realistic eye model. | LitMetric

Purpose: There is a growing trend towards the adoption of model-based calculation algorithms (MBDCAs) for brachytherapy dose calculations which can properly handle media and source/applicator heterogeneities. However, most of dose calculations in ocular plaque therapy are based on homogeneous water media and standard in-silico ocular phantoms, ignoring non-water equivalency of the anatomic tissues and heterogeneities in applicators and patient anatomy. In this work, we introduce EyeMC, a Monte Carlo (MC) model-based calculation algorithm for ophthalmic plaque brachytherapy using realistic and adaptable patient-specific eye geometries and materials.

Methods: We used the MC code PENELOPE in EyeMC to model Bebig IsoSeed I25.S16 seeds in COMS plaques and Ru/ Rh applicators that are coupled onto a customizable eye model with realistic geometry and composition. To significantly reduce calculation times, we integrated EyeMC with CloudMC, a cloud computing platform for radiation therapy calculations. EyeMC is equipped with an evaluation module that allows the generation of isodose distributions, dose-volume histograms, and comparisons with Plaque Simulator three-dimensional dose distribution. We selected a sample of patients treated with I and Ru isotopes in our institution, covering a variety of different type of plaques, tumor sizes, and locations. Results from EyeMC were compared to the original plan calculated by the TPS Plaque Simulation, studying the influence of heterogeneous media composition as well.

Results: EyeMC calculations for Ru plaques agreed well with manufacturer's reference data and data of MC simulations from Hermida et al. (2013). Significant deviations, up to 20%, were only found in lateral profiles for notched plaques. As expected, media composition significantly affected estimated doses to different eye structures, especially in the I cases evaluated. Dose to sclera and lens were found to be about 12% lower when considering real media, while average dose to tumor was 9% higher. Ru cases presented a 1%-3% dose reduction in all structures using real media for calculation, except for the lens, which showed an average dose 7.6% lower than water-based calculations. Comparisons with Plaque Simulator calculations showed large differences in dose to critical structures for Ru notched plaques. I cases presented significant and systematic dose deviations when using the default calculation parameters from Plaque Simulator version 5.3.8., which were corrected when using calculation parameters from a custom physics model for carrier-attenuation and air-interface correction functions.

Conclusions: EyeMC is a MC calculation system for ophthalmic brachytherapy based on a realistic and customizable eye-tumor model which includes the main eye structures with their real composition. Integrating this tool into a cloud computing environment allows to perform high-precision MC calculations of ocular plaque treatments in short times. The observed variability in eye anatomy among the selected cases justifies the use of patient-specific models.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.15045DOI Listing

Publication Analysis

Top Keywords

plaque simulator
12
dose
10
monte carlo
8
calculation
8
calculation system
8
system ophthalmic
8
ophthalmic brachytherapy
8
brachytherapy based
8
based realistic
8
eye model
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!