Background: This study aimed to establish a non-invasive and simple screening model of coronary atherosclerosis burden based on the associations between multiple blood parameters and total plaque score (TPS), segment-stenosis score (SSS), coronary artery disease severity (CADS) in coronary artery disease (CAD) and thus reduce unnecessary coronary angiography (CAG).

Methods: A total of 1,366 patients with suspected CAD who underwent CAG were included in this study. The clinical risk factors [age, gender, systolic blood pressure (SBP), diastolic blood pressure (DBP), total cholesterol (TC), high-density lipoprotein (HDL), triglyceride (TG), low-density lipoprotein (LDL), fasting plasma glucose (FPG), and glycated hemoglobin (GHB)] were collected. The presence of plaques and lumen stenosis was assessed based on CAG imaging. The TPS, SSS, and CADS were calculated, and the distribution spectrum of atherosclerotic plaques was described. Kruskal-Wallis test for multiple comparison tests was performed to analyze the differences in groups of different risk factors. The selected independent predictors were put into a multivariate logistic model, and the variables were further screened by stepwise regression to establish a screening model. Finally, the receiver operating characteristic (ROC) curve was used to evaluate the selected model's discriminant effect.

Results: The distributions of TPS and SSS scores were both right-skewed. Among males, both TPS and SSS scores were higher than in females (χ=46.7659, P<0.0001, χ=51.6603, P<0.0001). Both TPS and SSS scores increased with age (χ=123.4456, P<0.0001, χ=123.4456, P<0.0001). For TPS, the most common position was proximal left anterior descending artery (P-LAD, 51.39%). In SSS, the P-LAD plaque was highest: 0: 48.61%, 1: 10.32%, 2: 9.15%, and 3: 31.92%. The TPS score >5, SSS score >5, and CAD >0 were valuable indicators for SBP, FPG, TG, HDL, and GHB. In the model, TPS score >5, SSS score >5, and CADS >0, the area under ROC curve (AUC) was 0.753 [95% confidence interval (CI): 0.713 to 0.789], 0.728 (95% CI: 0.687 to 0.766), and 0.756 (95% CI: 0.717 to 0.793), respectively.

Conclusions: The most common site of lesions was P-LAD. These models can be used as non-invasive and simple initial screening tools without CAG.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8250030PMC
http://dx.doi.org/10.21037/qims-20-901DOI Listing

Publication Analysis

Top Keywords

coronary artery
12
artery disease
12
screening model
12
tps sss
12
distribution spectrum
8
spectrum atherosclerotic
8
atherosclerotic plaques
8
patients suspected
8
model coronary
8
coronary atherosclerosis
8

Similar Publications

The lumen centerline of the coronary artery allows vessel reconstruction used to detect stenoses and plaques. Discrete-action-based centerline extraction methods suffer from artifacts and plaques. This study aimed to develop a continuous-action-based method which performs more effectively in cases involving artifacts or plaques.

View Article and Find Full Text PDF

Patients with type 2 diabetes mellitus (DM) are more susceptible to microvascular complications. However, whether DM is associated with coronary microvascular dysfunction (CMD) is unclear. This observational study used data from the Coronary Microvascular Disease Registry (CMDR) (NCT05960474) and included patients with angina and no obstructive coronary artery disease (ANOCA) who underwent invasive CMD evaluation using the CoroVentis CoroFlow System (Abbott Vascular, Santa Clara, CA).

View Article and Find Full Text PDF

Acute Left Main Coronary Artery Compression After Harmony-TPV Implantation.

Catheter Cardiovasc Interv

January 2025

Toronto Congenital Cardiac Centre for Adults, Peter Munk Cardiac Centre, University Health Network, University of Toronto, Toronto, Ontario, Canada.

We present an 18-year-old male with Fallot's tetralogy (ToF) repaired with a transannular and main pulmonary artery (PA) patch, who suffered an acute coronary artery compression after a Harmony-TPV deployment. Left main coronary artery compression was confirmed with angiography and IVUS. He underwent emergent surgery, with a bioprosthetic valve replacement.

View Article and Find Full Text PDF

Background And Aims: Drug-eluting stents (DES) are not designed for overexpansion to supra-nominal diameters or intentional stent fracture (ISF). The optimal dilation technique to minimize stent shortening (SS) and achieve ISF to accommodate pediatric somatic growth has not been described.

Methods: Three sizes of two commonly used DES were implanted within a silicone model to simulate blood vessels.

View Article and Find Full Text PDF

Computational fluid dynamics to simulate stenotic lesions in coronary end-to-side anastomosis.

Interdiscip Cardiovasc Thorac Surg

January 2025

Department of Cardiovascular Surgery, Shiga University of Medical Science, Setatsukinowa, Otsu, Shiga, 520-2192, Japan.

Objectives: End-to-side anastomosis is common in coronary artery bypass grafting, although restrictive suturing can narrow the anastomosis. We evaluated ex vivo end-to-side models by numerically simulating fluid dynamics to compare various degrees of stenotic anastomoses to predict haemodynamic effects.

Methods: A carotid artery was grafted via an end-to-side anastomosis onto the left anterior descending artery of a porcine heart, with liquid silicone injected into the vessels.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!