Purpose: One of the preventive strategies for periprosthetic joint infection (PJI) is the use of antibiotic-loaded bone cement (ALBC) in primary total joint arthroplasty (TJA). Even though it is widely used, there are concerns about the development of antibacterial resistance. The aim of the study was to investigate whether using ALBC in primary TJA increases the antibiotic-resistant PJI. The hypothesis was that the regular use of ALBC does not increase the rate of resistant PJI.
Methods: Patients with confirmed PJI who had revision surgery from year 2010 to 2019 were included in this international multicenter study. The ALBC group was compared to the non-ALBC TJA group from the same time period. Medical records were used to collect clinical (age, gender, body mass index, comorbidities), TJA-related (type of operation, implant type and survival) and PJI-related (cultured microorganism, antibiogram) data. Resistance to gentamicin, clindamycin and vancomycin were recorded from the antibiograms. Multiple logistic regression model was used to identify risk factors and account for the potential confounders.
Results: 218 patients with PJI were included in the study: 142 with gentamicin-loaded bone cement and 76 in the non-ALBC group. The average age in the ALBC group was 71 ± 10 years and 62 ± 12 years in the comparison group (p < 0.001). Coagulase negative Staphylococci (CONS) were the most common (49%) isolated pathogens. The use of ALBC did not increase the rate of any resistant bacteria significantly (OR = 0.79 (0.42-1.48), p = 0.469). The presence of CONS was associated with higher risk of antibiotic resistance.
Conclusions: The current study demonstrates no increase in antibiotic resistance due to ALBC after primary TJA. Thus, the use of ALBC during primary TJA should not be feared in the context of antimicrobial resistance.
Level Of Evidence: III.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9418265 | PMC |
http://dx.doi.org/10.1007/s00167-021-06649-x | DOI Listing |
J Clin Med
January 2025
Discipline of Physiotherapy, Faculty of Health Sciences, European University Miguel de Cervantes, C del Padre Julio Chevalier 2, 47012 Valladolid, Spain.
: Hip fractures are prevalent among the elderly and impose a significant burden on healthcare systems due to the associated high morbidity and costs. The increasing use of intramedullary nails for hip fracture fixation has inadvertently introduced risks; these implants can alter bone elasticity and create stress concentrations, leading to peri-implant fractures. The aim of this study is to investigate the outcomes of peri-implant hip fractures, evaluate the potential causes of such fractures, determine the type of treatment provided, assess the outcomes of said treatments, and establish possible improvement strategies.
View Article and Find Full Text PDFPolymers (Basel)
January 2025
College of Science and General Studies, AlFaisal University, P.O. Box 50927, Riyadh 11533, Saudi Arabia.
Herein, we report the methodological impact on the curing kinetics of bone cement based on polymer nanocomposites prepared using different methods. Poly (styrene--methylmethacrylate)-2D nanofiller nanocomposites (P(S-MMA)-2D Nanofiller) were prepared using bulk and suspension polymerization methods to study the effect of the different methods. The prepared nanocomposites were well-characterized for chemical, thermal, mechanical, and structural characteristics using Fourier Transform Infrared spectroscopy (FT-IR), differential scanning calorimetry (DSC), nano-indentation, and scanning electron microscopy (SEM) techniques, respectively.
View Article and Find Full Text PDFJ Cosmet Dermatol
January 2025
College of Medicine, Department of Dermatology, Imam Mohammad Ibn Saud University, Riyadh, Saudi Arabia.
Background: Acne is a common condition observed in adolescents and in most severe acne the scars develop. There are numerous treatment options for acne scars. However, no standardized guidelines have been established to guide physicians in the optimal treatment of acne scars.
View Article and Find Full Text PDFClin Spine Surg
December 2024
Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjyuku, Tokyo.
Study Design: Multicenter retrospective cohort study.
Objective: To evaluate the efficacy and safety of using cement-augmented pedicle screw (CAPS) fixation only for the cephalad and caudal vertebral bodies.
Summary Of Background Data: Pedicle screw fixation is less effective in patients with low-quality bone.
PLoS One
January 2025
Departamento de Reología y Mecánica de Materiales, Instituto de Investigaciones en Materiales, Universidad Nacional Autónoma de México Ciudad Universitaria, Ciudad de México, México.
A hybrid coating made of poly (methyl methacrylate) with SiO2-TiO2 particles (PMMA/SiO2-TiO2) has been developed for use as a coating on nanosatellites, evaluating its resistance to high vacuum by quantifying its weight loss. The coating was applied on an Al 7075 aluminum substrate used for the aerospace sector. PMMA/SiO2-TiO2 hybrid coatings were prepared using sol-gel reaction in situ assisted with sonochemistry.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!