A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A durable microsecond solid-state pulsed power system. | LitMetric

A durable microsecond solid-state pulsed power system.

Rev Sci Instrum

College of Advanced Interdisciplinary Studies, National University of Defense Technology, Changsha 410073, China.

Published: May 2021

An all-solid-state microsecond pulsed power system has been tested in this paper. It can produce larger than 50 kV and microsecond-range pulses continuously for more than 9 × 10 shots into a resistive load at a repetition rate of 10 pps. The whole device has accumulatively operated more than 15 000 pulses at 100 Hz and 3 × 10 pulses at 10 Hz. This all-solid-state pulsed power system consists of a repetitive power supply, a four-stage Marx generator, a pulse forming network, and a resistive load. The repetitive power supply of the pulsed power system is calculated and analyzed first, followed by the introduction of the Marx generator and the three-section anti-resonance network. A polymer box of sodium chloride solution is applied as a resistive load with an impedance of 200 Ω. Repetitive experiments showed that this system is able to operate stably at 100 Hz repetition rate without failure.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0049795DOI Listing

Publication Analysis

Top Keywords

pulsed power
16
power system
16
resistive load
12
repetition rate
8
repetitive power
8
power supply
8
marx generator
8
power
6
system
5
durable microsecond
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!