A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development and first operation of a cavity ring down spectroscopy diagnostic in the negative ion source SPIDER. | LitMetric

The neutral beam injectors of the ITER experiment will rely on negative ion sources to produce 16.7 MW beams of H/D particles accelerated at 1 MeV. The prototype of these sources was built and is currently operated in the SPIDER (Source for the Production of Ions of Deuterium Extracted from a Radio frequency plasma) experiment, part of the Neutral Beam Test Facility of Consorzio RFX, Padua. In the SPIDER, the H/D ion source is coupled to a three grid, 100 kV acceleration system. One of the main goals of the experimentation in SPIDER is to uniformly maximize the extracted current density; to achieve this, it is important to study the density of negative ions available in the proximity of the ion acceleration system. In SPIDER, line-integrated measurements of negative ion density are performed by a cavity ring down spectroscopy diagnostic. Its principle of operation is based on the absorption of the photons of a laser beam pulse by H/D photo-detachment; the absorption detection is enhanced by trapping the laser pulse in an optical cavity, containing the absorbing medium (i.e., negative ions). This paper presents and discusses the CRDS diagnostic setup in the SPIDER, including the first measurements of negative ion density, correlated with the main source parameters.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0043226DOI Listing

Publication Analysis

Top Keywords

negative ion
16
cavity ring
8
ring spectroscopy
8
spectroscopy diagnostic
8
ion source
8
neutral beam
8
acceleration system
8
negative ions
8
measurements negative
8
ion density
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!