Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Fenoldopam is an approved drug used to treat hypotension. The purpose of this study is to develop and validate an LC-MS method to quantify fenoldopam and its major metabolites fenoldopam-glucuronide and fenoldopam-sulfate in plasma and apply the method to a pharmacokinetic study in rats. A Waters C column was used with 0.1% formic acid in acetonitrile and 0.1% formic acid in water as the mobile phases to elute the analytes. A positive-negative switching method was performed in a triple quadrupole mass spectrometer using Multiple Reaction Monitoring (MRM) mode. A one-step protein precipitation using methanol and ethyl acetate was successfully applied for plasma sample preparation. The method was validated following the FDA guidance. The results show that the LLOQ of fenoldopam, fenoldopam-glucuronide and fenoldopam-sulfate is 0.98, 9.75 and 0.98 nM, respectively. The intraday and interday variance is less than 8.4% and the accuracy is between 82.5 and 116.0 %. The extraction recovery for these three analytes ranged from 81.3 ± 4.1% to 113.9 ± 13.2%. There was no significant matrix effect and no significant degradation under the experimental conditions. PK studies showed that fenoldopam was rapidly eliminated (t = 0.63 ± 0.24 h) from the plasma and glucuronide is the major metabolite. This method was suitably selective and sensitive for pharmacokinetic and phase II metabolism studies.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8403159 | PMC |
http://dx.doi.org/10.1016/j.jchromb.2021.122854 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!