A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Marginal and internal fit of crowns based on additive or subtractive manufacturing. | LitMetric

Marginal and internal fit of crowns based on additive or subtractive manufacturing.

Biomater Investig Dent

Department of Dentistry and Oral Health, Section for Prosthodontics, Aarhus University, Aarhus, Denmark.

Published: June 2021

Objective: To assess the marginal and internal fit of crowns manufactured by additive and subtractive manufacturing technique.

Materials And Methods: Twenty extracted teeth prepared for complete coverage crowns were scanned with an intra-oral scanner (Omnicam, DentsplySirona). For the subtractive manufacturing (SM) group, ten crowns were manufactured in a hybrid resin block (Vita Enamic, Vita Zahnfabrik). For the additive manufacturing (AM) group, the crowns were manufactured in a hybrid resin material (NextDent C&B, 3D systems). The design parameters were identical for the two groups. The marginal and internal fit (determined at the axial wall, the cusp tip and occlusally) was assessed before cementation with the replica technique and after cementation under stereomicroscope after sectioning of the crowned teeth.

Results: For the SM group, the marginal fit was 91 µm (±28 µm) before cementation and 85 µm (±18 µm) after cementation. In the AM group, the marginal fit was 75 µm (±29 µm) before cementation and 71 µm (±18 µm) after cementation. The differences were not statistically significant. As regards the internal fit, the fit at the axial wall was statistically significantly better in the SM group than in the AM group (=.009 before cementation and .03 after cementation). Occlusally the fit in the AM group was significantly better than in the SM group after cementation (<.001).

Conclusion: Within the limitations of the current study, the marginal fit of additively manufactured crowns is comparable to crowns manufactured with chair-side subtractive technique and within the clinically acceptable range. As regards the internal fit no one technique was consistently superior.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8238058PMC
http://dx.doi.org/10.1080/26415275.2021.1938576DOI Listing

Publication Analysis

Top Keywords

internal fit
16
marginal internal
12
subtractive manufacturing
12
crowns manufactured
12
µm cementation
12
cementation
9
fit
8
fit crowns
8
additive subtractive
8
group
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!