The Feasibility of C1-C2 Screw-rod Fixation in the Children 5 Years of Age and Younger.

J Pediatr Orthop

Center for Spine Surgery, Orthopedics and Traumatology, SRH-Klinikum Karlsbad-Langensteinbach, Karlsbad, Germany.

Published: September 2021

Background: Atlantoaxial fixation is technically challenging in younger children. The C1-C2 screw-rod fixation technique is established for adults but limited data about the clinical and radiographical outcome for the treatment of children with 5 years of age or younger is available.

Methods: All files of children who were consecutively treated for spinal disorders were reviewed. Inclusion criteria for further evaluation were: 0 to 5 years of age at initial procedure; detailed surgical report of a posterior C1-C2 fusion with mass lateral and pedicle screw-rod fixation as described by Harms; a minimum clinical and radiographical follow-up of 24 months. The postoperative and last follow-up computed tomography scan and radiographs were used to assess the positioning and stability of the C1-C2 screw-rod construct.

Results: Eleven patients (3 boys) with a mean age of 46 months (range: 8 to 66 mo) fulfilled inclusion criteria and were evaluated retrospectively. The mean clinical and radiographical follow-up was 79 months (range: 24 mo to 170 mo). The diagnosis was atlantoaxial rotatory dislocation (4 cases), C1-C2 instability with subluxation (3 cases), atlantoaxial dislocation and os odontoideum (1 case), type II odontoid fracture (1 case), traumatic odontoid epiphysiolysis (1 case), and traumatic rupture of the transverse ligament with C1 subluxation (1 case). Intraoperatively and postoperatively no new neurovascular or vascular complication occurred. C1 lateral mass screws were placed correctly in all cases. Twenty-two C2 pedicle screws were placed correctly (85.7%), and 3 screws showed penetration of the pedicle wall (14.3%). No implant revision, implant failure, and pseudarthrosis were noted. Loss of correction was noted in 1 patient with unilateral C1-C2 fixation and a repeated dorsal fusion procedures were performed. A repeat procedure for implant removal and segmental release was performed in 3 patients to increase the axial rotation of the head.

Conclusions: The C1-C2 screw-rod fixation is a safe technique that achieves solid fixation of the atlantoaxial complex in young children with various disorders. The technique preserves the joint and allows for segmental release via implant removal.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BPO.0000000000001899DOI Listing

Publication Analysis

Top Keywords

c1-c2 screw-rod
16
screw-rod fixation
16
years age
12
clinical radiographical
12
children years
8
age younger
8
inclusion criteria
8
radiographical follow-up
8
follow-up months
8
months range
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!