Background: Prosthetic joint infection (PJI) is a devastating complication. Studies have suggested reduction in PJI with the use of ceramic bearings.

Methods: Adult patients who underwent total hip arthroplasty (THA) using an uncemented acetabular component with ceramic-on-ceramic (CoC), ceramic-on-polyethylene (CoP), or metal-on-polyethylene (MoP) bearing surfaces between 2002 and 2016 were extracted from the National Joint Registry for England, Wales, Northern Ireland, and the Isle of Man. A competing risk regression model to investigate predictors of each revision outcome was used. Time-to-event was determined by duration of implantation since primary surgery with competing risks being death or revision. The results were adjusted for age, gender, American Association of Anaesthesiologists grade, body mass index, surgical indication, intraoperative complications, and implant data.

Results: In total, 456,457 THAs (228,786 MoP, 128,403 CoC, and 99,268 CoP) were identified. Multivariable modeling showed that the risk of revision for PJI was significantly lower with CoC (risk ratio 0.748, P < .001) and CoP (risk ratio 0.775, P < .001) compared to MoP. Significant reduction in risk of aseptic and all-cause revision was also seen. The significant protective effect of ceramic bearing was predominantly seen 2 years after implantation. Aseptic revision beyond 2 years reduced by 18.1% and 24.8% for CoC and CoP (P < .001), respectively. All-cause revision rate beyond 2 years reduced by 21.6% for CoC and 27.1% for CoP (P < .001) CONCLUSION: This study demonstrates an association between the use of ceramic as part of the bearing, with lower rates of revision for all causes, revision for infection, and revision for aseptic causes, supporting ceramic bearings in THA.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2021.05.027DOI Listing

Publication Analysis

Top Keywords

revision
10
ceramic bearings
8
revision rate
8
hip arthroplasty
8
national joint
8
joint registry
8
registry england
8
england wales
8
wales northern
8
northern ireland
8

Similar Publications

Introduction: Patients with psoriasis (PsO) and permanent spinal cord injuries (SCI) resulting in paraplegia and tetraplegia may experience a higher rate of infections compared to patients with PsO without SCI. It can result in further challenges for therapeutic management with immunosuppressants (biological and non-biological treatments). Thus,  we aimed to evaluate the rate of infections in patients with PsO and SCI treated with systemic immunosuppressants.

View Article and Find Full Text PDF

Introduction: Manipulation under anesthesia (MUA) is a standard and effective treatment to correct stiffness and improve range of motion (ROM) following total knee arthroplasty (TKA). Delayed MUA has been associated with increased rates of revision surgeries and infections. Early MUA has been shown to double the mean gain in flexion compared to delayed interventions.

View Article and Find Full Text PDF

The traditional Chinese medicine compound preparation known as Jinbei Oral Liquid (JBOL) consists of 12 herbs, including Astragalus membranaceus (Fisch.) Bge, Codonopsis pilosula (Franch.) Nannf, et al.

View Article and Find Full Text PDF

Introduction: Two-stage revision is considered the gold standard treatment in chronic periprosthetic joint infection (PJI) but no specific criteria or examination exist to determine infection eradication before reimplantation. This study aimed to assess the diagnostic performance of leukocyte scintigraphy after the first-stage procedure in two-stage revision for chronic PJI.

Material And Methods: Patients studied with leukocyte scintigraphy after cement spacer insertion for knee PJI from January 2012 to December 2021 were retrospectively included.

View Article and Find Full Text PDF

Clinical utility of hematological parameters in aplastic anemia.

Sci Rep

January 2025

Department of Laboratory Medicine, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan, 030032, China.

Hematological parameters available on automated hematology analyzers have been shown to be useful indicators for hematological disorders. However, extensive studies especially in aplastic anemia for these indices are sparse. Our aim was to investigate the clinical utility of hematological parameters in aplastic anemia.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!