Biomechanical properties of ascending aortic aneurysms: Quantification of inter- and intra-patient variability.

J Biomech

Department of Civil Engineering, University of Calgary, Calgary, Canada; Libin Cardiovascular Institute of Alberta, University of Calgary, Calgary, Canada; Centre for Bioengineering Research and Education, University of Calgary, Calgary, Canada. Electronic address:

Published: August 2021

This study investigates the biomechanical properties of ascending aortic aneurysms focusing on the inter-patient differences vs. the heterogeneity within a patient's aneurysm. Each specimen was tested on a biaxial testing device and the resulting stress-strain response was fitted to a four-parameter Fung constitutive model. We postulate that the inter-patient variability (differences between patients) blurs possible intra-patient variability (regional heterogeneity) and, thus, that both effects must be considered to shed light on the role of heterogeneity in aneurysm progression. We propose, demonstrate, and discuss two techniques to assess differences by, first, comparing conventional biomechanical properties and, second, the overall constitutive response. Results show that both inter- and intra-patient variability contribute to errors when using population averaged models to fit individual tissue behaviour. When inter-patient variability was accounted for and its effects excluded, intra-patient heterogeneity could be assessed, showing a wide degree of heterogeneity at the individual patient level. Furthermore, the right lateral region (from the patient's perspective) appeared different (stiffer) than the other regions. We posit that this heterogeneity could be a consequence of maladaptive remodelling due to altered loading conditions that hastens microstructural changes naturally occurring with age. Further validation of these results should be sought from a larger cohort study.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbiomech.2021.110542DOI Listing

Publication Analysis

Top Keywords

biomechanical properties
12
intra-patient variability
12
properties ascending
8
ascending aortic
8
aortic aneurysms
8
inter- intra-patient
8
inter-patient variability
8
heterogeneity
6
variability
5
aneurysms quantification
4

Similar Publications

Evaluation of the Effectiveness of Using LED Light Combined With Chromophore Gel in Treating Acne Vulgaris - Preliminary Study.

Clin Cosmet Investig Dermatol

January 2025

Department of Basic Biomedical Science, Faculty of Pharmaceutical Sciences in Sosnowiec, Medical University of Silesia in Katowice, Sosnowiec, Poland.

Purpose: The aim was to quantitatively evaluate the effectiveness of LED light therapy combined with photoacceptor substances having anti-acne properties in reducing the symptoms of acne vulgaris.

Patients And Methods: 15 subjects aged 20 to 24 who suffered from moderate or severe acne lesions. The treatments were performed using a LED device (465-880 nm).

View Article and Find Full Text PDF

Background: Glaucoma, particularly open-angle glaucoma (OAG), is a leading cause of irreversible blindness, associated with optic nerve damage, retinal ganglion cell death, and visual field defects. Corneal biomechanical properties and cellular components, such as corneal nerve and keratocyte densities assessed by in vivo confocal microscopy (IVCM), may serve as biomarkers for glaucoma progression. This study aimed to explore the relationship between corneal nerve parameters, keratocyte density, and optical coherence tomography (OCT)-derived retinal nerve fiber layer (RNFL) thickness in primary open-angle glaucoma (POAG) patients and controls.

View Article and Find Full Text PDF

Fabrication of a micropatterned shape-memory polymer patch with L-DOPA for tendon regeneration.

Biomater Sci

January 2025

Department of Nanobiomedical Science & BK21 FOUR micropatterned shape-memory NBM Global Research Center for Regenerative Medicine, Dankook University, Cheonan 31116, Republic of Korea.

A scaffold design for tendon regeneration has been proposed, which mimics the microstructural features of tendons and provides appropriate mechanical properties. We synthesized a temperature-triggered shape-memory polymer (SMP) using the ring-opening polymerization of polycaprolactone (PCL) with polyethylene glycol (PEG) as a macroinitiator. We fabricated a micropatterned patch using SMP capillary force lithography, which mimicked a native tendon, for providing physical cues and guiding effects.

View Article and Find Full Text PDF

Objective: Reverse obliquity intertrochanteric fracture is an unstable type of fracture. Current guidelines recommend intramedullary fixation, but there are still complications such as screw removal, hip varus, nail withdrawal, and nail fracture. The objective of this study was to use finite element analysis to compare the biomechanical properties of the novel proximal femoral bionic nail (PFBN), proximal femoral nail antirotation (PFNA), and combined compression interlocking intramedullary nail (InterTan) in the treatment of reverse obliquity intertrochanteric fractures (AO/OTA 31-A3.

View Article and Find Full Text PDF

Soft tissue-like coupling materials for in vitro acoustic emission studies in total hip arthroplasty.

J Mech Behav Biomed Mater

January 2025

Laboratory for Biomechanics and Biomaterials (LBB), Department of Orthopedic Surgery, Hannover Medical School, Anna-von-Borries-Strasse 1-7, 30625, Hannover, Germany. Electronic address:

In hip arthroplasty, relative movements between the femoral stem and bone can lead to implant loosening, resulting in extensive bone loss. Acoustic emission (AE) analysis is a promising technique for a nondestructive and noninvasive detection of these relative movements. To develop such a detection method, in vitro investigations using piezoelectric AE sensors on implant stems in artificial or human femora are required to characterize the AE signals induced by loosening.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!