Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: We aimed to investigate the feasibility of multi-acquisition with variable resonance image combination slab selectivity inversion recovery (MAVRIC SL IR) sequence on 3.0 T MRI in patients with anterior cervical discectomy and fusion (ACDF) surgery compared to bandwidth-optimized short tau inversion recovery (STIR) sequence.
Methods: Paired sagittal MR images of MAVRIC SL IR and bandwidth-optimized STIR sequences were acquired and analyzed for 21 patients after ACDF surgery with PEEK cage-plate construct. Quantitative comparisons were made on the metal artifact areas of paired mid-sagittal images. In qualitative analysis, the consistency of fat suppression and visibility of anatomic structures (bonemetal interface, surrounding soft tissues, and spinal cord) were independently assessed, based on a five-point scale by two musculoskeletal radiologists, who were blind to the images and patient details.
Results: The application of the MAVRIC SL IR sequence resulted in a significant reduction of 48% in the mean area of metal artifacts (t = -7.141, p < 0.001). Based on the comments received from both the reviewers, the MAVRIC SL IR sequence showed greater visibility of the bone-metal interface (p < 0.001), considerable visibility of the surrounding soft tissues (p > 0.05) but worse visibility of the spinal cord (p < 0.001), including the consistency of fat suppression (p < 0.001) relative to the bandwidth-optimized STIR sequence.
Conclusion: With significantly reduced metal artifacts, the MAVRIC SL IR sequence can be implemented in patients undergoing ACDF surgery with PEEK cage-plate construct for 3.0 T MRI, despite the poor visibility of the spinal cord.