A Study on the Bending Stiffness of a New DNA Origami Nano-Joint.

Mol Biotechnol

Department of Mechanical Engineering, Hakim Sabzevari University, Sabzevar, Iran.

Published: November 2021

The present article aims to investigate the mechanical properties of a new DNA origami nano-joint using the steered molecular dynamics (SMD) simulation. Since the analysis of mechanical properties is of great importance in bending conditions for a nano-joint, the forces are selected to achieve angular changes in the joint by the resultant torque. In this study, the nano-joint is considered as a beam in order to use mechanical equations to extract the mechanical properties of the designed nano-joint. In addition, the bending stiffness of the beam is investigated in different modes of deflection using the Euler-Bernoulli beam theory. The results revealed that the value of bending stiffness increases with increasing deflection, and the changes in the bending stiffness relative to the deflection is linear. The proposed DNA origami nano-joint can be used as a joint in nanorobots and can be effectively applied in nanorobotic systems to move different components.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12033-021-00367-yDOI Listing

Publication Analysis

Top Keywords

bending stiffness
16
dna origami
12
origami nano-joint
12
mechanical properties
12
nano-joint
6
study bending
4
stiffness
4
stiffness dna
4
nano-joint article
4
article aims
4

Similar Publications

We analyzed the intrinsic strength of distal and proximal FeN bonds and the stiffness of the axial NFeN bond angle in a series of cytochrome b5 proteins isolated from various species, including bacteria, animals, and humans. Ferric and ferrous oxidation states were considered. As assess- ment tool, we employed local vibrational stretching force constants ka(FeN) and bending force constants ka(NFeN) derived from our local mode theory.

View Article and Find Full Text PDF

The issues of numerous steel beam components and the tendency for deck cracking under negative bending moment zones have long been challenges faced by traditional composite I-beams with flat steel webs. This study introduces an optimized approach by modifying the structural design and material selection, specifically substituting flat steel webs with corrugated steel webs and using ultra-high-performance concrete for the deck in the negative bending moment zone. Three sets of model tests were conducted to compare and investigate the influence of deck material and web forms on the bending and crack resistance of steel-concrete composite I-beams under a negative bending moment zone.

View Article and Find Full Text PDF

The key structural components of a wind turbine blade, such as the skin, spar cap, and shear web, are fabricated from fiber-reinforced composite materials. The spar, predominantly manufactured via resin infusion-a process of resin injection and curing in carbon fibers-is prone to initial defects, such as pores, wrinkles, and delamination. This study suggests employing the pultrusion technique for spar production to consistently obtain a uniform cross-section and augment the reliability of both the manufacturing process and the design.

View Article and Find Full Text PDF

Animal muscles have complex, three-dimensional structures with fibers oriented in various directions. The tongue, in particular, features a highly intricate muscular system composed of four intrinsic muscles and several types of extrinsic muscles, enabling flexible and diverse movements essential for feeding, swallowing, and speech production. Replicating these structures could lead to the development of multifunctional manipulators and advanced platforms for studying muscle-motion relationships.

View Article and Find Full Text PDF

Fracture resistances of heat-treated nickel-titanium files used for minimally invasive instrumentation.

BMC Oral Health

January 2025

Department of Conservative Dentistry, School of Dentistry, Dental Research Institute, Dental and Life Science Institute, Pusan National University, Yangsan, Korea.

Background: This study compared the torsional resistance, bending stiffness, and cyclic fatigue resistances of different heat-treated NiTi files for minimally invasive instrumentation.

Methods: TruNatomy (TN) and EndoRoad (ER) file systems were compared with ProTaper Gold (PG). Torsional load, distortion angle, and bending stiffness were assessed using a custom device AEndoS, and toughness was calculated using the torsional data.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!