A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Higher resuscitation guideline adherence in paramedics with use of real-time ventilation feedback during simulated out-of-hospital cardiac arrest: A randomised controlled trial. | LitMetric

Objectives: To investigate whether real-time ventilation feedback would improve provider adherence to ventilation guidelines.

Design: Non-blinded randomised controlled simulation trial.

Setting: One Emergency Medical Service trust in Copenhagen.

Participants: 32 ambulance crews consisting of 64 on-duty basic or advanced life support paramedics from Copenhagen Emergency Medical Service.

Intervention: Participant exposure to real-time ventilation feedback during simulated out-of-hospital cardiac arrest.

Main Outcome Measures: The primary outcome was ventilation quality, defined as ventilation guideline-adherence to ventilation rate (8-10 bpm) and tidal volume (500-600 ml) delivered simultaneously.

Results: The intervention group performed ventilations in adherence with ventilation guideline recommendations for 75.3% (Interquartile range (IQR) 66.2%-82.9%) of delivered ventilations, compared to 22.1% (IQR 0%-44.0%) provided by the control group. When controlling for participant covariates, adherence to ventilation guidelines was 44.7% higher in participants receiving ventilation feedback. Analysed separately, the intervention group performed a ventilation guideline-compliant rate in 97.4% (IQR 97.1%-100%) of delivered ventilations, versus 66.7% (IQR 40.9%-77.9%) for the control group. For tidal volume compliance, the intervention group reached 77.5% (IQR 64.9%-83.8%) of ventilations within target compared to 53.4% (IQR 8.4%-66.7%) delivered by the control group.

Conclusions: Real-time ventilation feedback increased guideline compliance for both ventilation rate and tidal volume (combined and as individual parameters) in a simulated OHCA setting. Real-time feedback has the potential to improve manual ventilation quality and may allow providers to avoid harmful hyperventilation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8244327PMC
http://dx.doi.org/10.1016/j.resplu.2021.100082DOI Listing

Publication Analysis

Top Keywords

ventilation feedback
20
real-time ventilation
16
ventilation
14
adherence ventilation
12
tidal volume
12
intervention group
12
feedback simulated
8
simulated out-of-hospital
8
out-of-hospital cardiac
8
randomised controlled
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!