Operator-dependent variability of angiography-derived fractional flow reserve and the implications for treatment.

Eur Heart J Digit Health

Department of Infection, Immunity and Cardiovascular Disease, Mathematical Modelling in Medicine Group, University of Sheffield, Beech Hill Road, Sheffield S102RX, UK.

Published: June 2021

AI Article Synopsis

  • The study aimed to assess how operator experience affects the accuracy of virtual fractional flow reserve (vFFR) in patients undergoing percutaneous coronary intervention.
  • Expert operators consistently showed lower variability and higher agreement in vFFR results compared to non-experts, which influenced treatment decisions in a significant number of cases.
  • The findings underscore the need for adequate training and quality assurance to ensure reliable vFFR outcomes for better patient management.

Article Abstract

Aims: To extend the benefits of physiologically guided percutaneous coronary intervention to many more patients, angiography-derived, or 'virtual' fractional flow reserve (vFFR) has been developed, in which FFR is computed, based upon the images, instead of being measured invasively. The effect of operator experience with these methods upon vFFR accuracy remains unknown. We investigated variability in vFFR results based upon operator experience with image-based computational modelling techniques.

Methods And Results: Virtual fractional flow reserve was computed using a proprietary method (VIRTUheart) from the invasive angiograms of patients with coronary artery disease. Each case was processed by an expert (>100 vFFR cases) and a non-expert (<20 vFFR cases) operator and results were compared. The primary outcome was the variability in vFFR between experts and non-experts and the impact this had upon treatment strategy (PCI vs. conservative management). Two hundred and thirty-one vessels (199 patients) were processed. Mean non-expert and expert vFFRs were similar overall [0.76 (0.13) and 0.77 (0.16)] but there was significant variability between individual results (variability coefficient 12%, intraclass correlation coefficient 0.58), with only moderate agreement ( = 0.46), and this led to a statistically significant change in management strategy in 27% of cases. Variability was significantly lower, and agreement higher, for expert operators; a change in their recommended management occurred in 10% of repeated expert measurements and 14% of inter-expert measurements.

Conclusion: Virtual fractional flow reserve results are influenced by operator experience of vFFR processing. This had implications for treatment allocation. These results highlight the importance of training and quality assurance to ensure reliable, repeatable vFFR results.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8242185PMC
http://dx.doi.org/10.1093/ehjdh/ztab012DOI Listing

Publication Analysis

Top Keywords

fractional flow
12
flow reserve
12
operator experience
8
operator-dependent variability
4
variability angiography-derived
4
angiography-derived fractional
4
reserve implications
4
implications treatment
4
treatment aims
4
aims extend
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!