Background: Tibial shaft fractures are the most common long-bone injury, with a reported annual incidence of more than 75 000 in the United States. This study aimed to determine whether patients with tibial fractures managed with intramedullary nails experience a lower rate of reoperation if treated at higher-volume hospitals, or by higher-volume or more experienced surgeons.
Methods: The Study to Prospectively Evaluate Reamed Intramedullary Nails in Patients with Tibial Fractures (SPRINT) was a multicentre randomized clinical trial comparing reamed and nonreamed intramedullary nailing on rates of reoperation to promote fracture union, treat infection or preserve the limb in patients with open and closed fractures of the tibial shaft. Using data from SPRINT, we quantified centre and surgeon volumes into quintiles. We performed analyses adjusted for type of fracture (open v. closed), type of injury (isolated v. multitrauma), gender and age for the primary outcome of reoperation using multivariable logistic regression.
Results: There were no significant differences in the odds of reoperation between high- and low-volume centres (p = 0.9). Overall, surgeon volume significantly affected the odds of reoperation (p = 0.03). The odds of reoperation among patients treated by moderate-volume surgeons were 50% less than those among patients treated by verylow-volume surgeons (odds ratio [OR] 0.50, 95% confidence interval [CI] 0.28–0.88), and the odds of reoperation among patients treated by high-volume surgeons were 47% less than those among patients treated by very-low-volume surgeons (OR 0.53, 95% CI 0.30–0.93).
Conclusion: There appears to be no significant additional patient benefit in treatment by a higher-volume centre for intramedullary fixation of tibial shaft fractures. Additional research on the effects of surgical and clinical site volume in tibial shaft fracture management is needed to confirm this finding. The odds of reoperation were higher in patients treated by very-low-volume surgeons; this finding may be used to optimize the results of tibial shaft fracture management. Clinical trial registration: ClinicalTrials.gov, NCT00038129
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8410470 | PMC |
http://dx.doi.org/10.1503/cjs.004020 | DOI Listing |
Bone Joint Res
January 2025
Department of Mechanical Engineering & Mechanics, Lehigh University, Bethlehem, Pennsylvania, USA.
Aims: The "2 to 10% strain rule" for fracture healing has been widely interpreted to mean that interfragmentary strain greater than 10% predisposes a fracture to nonunion. This interpretation focuses on the gap-closing strain (axial micromotion divided by gap size), ignoring the region around the gap where osteogenesis typically initiates. The aim of this study was to measure gap-closing and 3D interfragmentary strains in plated ovine osteotomies and associate local strain conditions with callus mineralization.
View Article and Find Full Text PDFCureus
November 2024
Information Technology, Mandayam Osuri Parthasarathi Vaishnav College for Women, Chennai, IND.
Introduction: Intramedullary interlocking nailing is a common surgical procedure for tibial fractures, enabling early patient mobilization. Traditionally, the infrapatellar approach has been used for intramedullary interlocking nailing of tibial fractures, but the suprapatellar approach is gaining attention for its potential benefits. This randomized controlled study aimed to compare the duration of the surgery, intra-operative blood loss, and fluoroscopy time between the suprapatellar and infrapatellar approaches.
View Article and Find Full Text PDFJ Funct Biomater
December 2024
Innovative Implant Development (Fracture Healing), Departments and Institutes of Surgery, Saarland University, 66421 Homburg, Germany.
Bone fractures are associated with hypoxia, but no longitudinal studies of perfusion measurements in human patients have been reported despite the clinical and research potential. In this longitudinal observational cohort study, the near-infrared spectroscopy (NIRS) device PortaMon was used to assess oxy-(OHb), deoxy-(HHb) and total (tHb) haemoglobin, as well as the differences between OHb and HHb (Hb) and the tissue saturation index (TSI) at three different depths in the fracture gap. Linear mixed effect models were fitted to analyse time effects.
View Article and Find Full Text PDFJBJS Essent Surg Tech
December 2024
Department of Orthopaedics and Rehabilitation, Yale School of Medicine, New Haven, Connecticut.
Background: For complete disruption of the posterolateral corner (PLC) structures, operative treatment is most commonly advocated, as nonoperative treatment has higher rates of persistent lateral laxity and posttraumatic arthritis. Some studies have shown that acute direct repair results in revision rates upwards of 37% to 40% compared with 6% to 9% for initial reconstruction. In a recent study assessing the outcomes of acute repair of PLC avulsion injuries with 2 to 7 years of follow-up, patients with adequate tissue were shown to have a much lower failure rate than previously documented.
View Article and Find Full Text PDFJ Pediatr Orthop B
December 2024
Department of Orthopaedic Surgery, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA.
All-terrain vehicle (ATV) accidents frequently cause orthopedic injuries. Previous studies have reported the frequency of fractures in ATV injuries. No studies have provided detailed assessments of fracture patterns, types of operative intervention, or risks for multiple surgeries.