Purpose: Noninvasive cardiac radioablation is increasingly used for treatment of refractory ventricular tachycardia. Attempts to limit normal tissue exposure are important, including managing motion of the target. An interplay between cardiac and respiratory motion exists for cardiac radioablation, which has not been studied in depth. The objectives of this study were to estimate target motion during abdominal compression free breathing (ACFB) and respiratory gated (RG) deliveries and to investigate the quality of either implanted cardioverter defibrillator lead tip or the diaphragm as a gating surrogate.
Methods And Materials: Eleven patients underwent computed tomography (CT) simulation with an ACFB 4-dimensional CT (r4DCT) and an exhale breath-hold cardiac 4D-CT (c4DCT). The target, implanted cardioverter defibrillator lead tip and diaphragm trajectories were measured for each patient on the r4DCT and c4DCT using rigid registration of each 4D phase to the reference (0%) phase. Motion ranges for ACFB and exhale (40%-60%) RG delivery were estimated from the target trajectories. Surrogate quality was estimated as the correlation with the target motion magnitudes.
Results: Mean (range) target motion across patients from r4DCT was as follows: left/right (LR), 3.9 (1.7-6.9); anteroposterior (AP), 4.1 (2.2-5.4); and superoinferior (SI), 4.7 (2.2-7.9) mm. Mean (range) target motion from c4DCT was as follows: LR, 3.4 (1.0-4.8); AP, 4.3 (2.6-6.5); and SI, 4.1 (1.4-8.0) mm. For an ACFB, treatment required mean (range) margins to be 4.5 (3.1-6.9) LR, 4.8 (3-6.5) AP, and 5.5 (2.3-8.0) mm SI. For RG, mean (range) internal target volume motion would be 3.6 (1.1-4.8) mm LR, 4.3 (2.6-6.5) mm AP, and 4.2 (2.2-8.0) mm SI. The motion correlations between the surrogates and target showed a high level of interpatient variability.
Conclusions: In ACFB patients, a simulated exhale-gated approach did not lead to large projected improvements in margin reduction. Furthermore, the variable correlation between readily available gating surrogates could mitigate any potential advantage to gating and should be evaluated on a patient-specific basis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijrobp.2021.06.035 | DOI Listing |
Cureus
December 2024
Department of Clinical Anatomy, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo, JPN.
Background: Sleep disturbances are common and distressing among patients with atopic dermatitis (AD), often resulting in a cycle of worsening skin conditions. Among various factors affecting sleep in AD, cervical spine movement has been suggested to influence sleep quality; however, these studies mostly relied on subjective measures. Owing to the lack of objective and quantitative analyses of cervical spine movement, its association with sleep disturbances remains poorly understood.
View Article and Find Full Text PDFClin Transl Radiat Oncol
March 2025
Department of Radiation Oncology, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany.
Purpose: To use imaging data from stereotactic MR-guided online adaptive radiotherapy (SMART) of ultracentral lung tumors (ULT) for development of a safe non-adaptive approach towards stereotactic body radiotherapy (SBRT) of ULT.
Patients And Methods: Analysis is based on 19 patients with ULT who received SMART (10 × 5.0-5.
J Oral Facial Pain Headache
March 2024
Faculty of business and Social Sciences, University of Applied Sciences, 49076 Osnabrück, Germany.
To test the effectiveness of an 8-week exercise program targeted to the neck muscles compared to manual therapy, and placebo treatments on orofacial pain intensity, jaw function, oral health-related quality of life (OHRQoL), and jaw range of motion (ROM) in women with Temporomandibular Disorders (TMD). In this randomized controlled trial, fifty-four women (between 18-45 years old) with a diagnosis of myofascial or mixed TMD according to the Research Diagnostic Criteria for TMD (RDC/TMD) were randomized into three groups: Neck motor control training (NTG), Manual Therapy Group (MTG), and Placebo Group (PG). All patients were evaluated with the Visual Analog Scale, Mandibular Function Impairment Questionnaire, Oral Health Impact Profile-14, and jaw Range of Motion (ROM) at baseline, immediately after treatment (after 8 weeks of treatment), one month, and three-month follow-up.
View Article and Find Full Text PDFElife
January 2025
Eikon Therapeutics Inc, Hayward, United States.
The regulation of cell physiology depends largely upon interactions of functionally distinct proteins and cellular components. These interactions may be transient or long-lived, but often affect protein motion. Measurement of protein dynamics within a cellular environment, particularly while perturbing protein function with small molecules, may enable dissection of key interactions and facilitate drug discovery; however, current approaches are limited by throughput with respect to data acquisition and analysis.
View Article and Find Full Text PDFJ Vis
January 2025
Neuroscience Program, University of Western Ontario, London, Ontario, Canada.
Human performance in perceptual and visuomotor tasks is enhanced when stimulus motion follows the laws of gravitational physics, including acceleration consistent with Earth's gravity, g. Here we used a manual interception task in virtual reality to investigate the effects of trajectory shape and orientation on interception timing and accuracy. Participants punched to intercept a ball moving along one of four trajectories that varied in shape (parabola or tent) and orientation (upright or inverted).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!