A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The mortality analysis of primary prevention patients receiving a cardiac resynchronization defibrillator (CRT-D) or implantable cardioverter-defibrillator (ICD) according to guideline indications in the improve SCA study. | LitMetric

Background: In primary prevention (PP) patients the utilization of implantable cardioverter-defibrillators (ICD) and cardiac resynchronization therapy-defibrillators (CRT-D) remains low in many geographies, despite the proven mortality benefit.

Purpose: The objective of this analysis was to examine the mortality benefit in PP patients by guideline-indicated device type: ICD and CRT-D.

Methods: Improve sudden cardiac arrest was a prospective, nonrandomized, nonblinded multicenter trial that enrolled patients from regions where ICD utilization is low. PP patient's CRT-D or ICD eligibility was based upon the 2008 ACC/AHA/HRS and 2006 ESC guidelines. Mortality was assessed according to guideline-indicated device type comparing implanted and nonimplanted patients. Cox proportional hazards methods were used, adjusting for known factors affecting mortality risk.

Results: Among 2618 PP patients followed for a mean of 20.8 ± 10.8 months, 1073 were indicated for a CRT-D, and 1545 were indicated for an ICD. PP CRT-D-indicated patients who received CRT-D therapy had a 58% risk reduction in mortality compared with those without implant (adjusted hazard ratio [HR]: 0.42, 95% confidence interval [CI]: 0.28-0.61, p < .0001). PP patients with an ICD indication had a 43% risk reduction in mortality with an ICD implant compared with no implant (adjusted HR: 0.57, 95% CI: 0.41-0.81, p = .002).

Conclusions: This analysis confirms the mortality benefit of adherence to guideline-indicated implantable defibrillation therapy for PP patients in geographies where ICD therapy was underutilized. These results affirm that medical practice should follow clinical guidelines when choosing therapy for PP patients who meet the respective defibrillator device implant indication.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jce.15149DOI Listing

Publication Analysis

Top Keywords

primary prevention
8
prevention patients
8
cardiac resynchronization
8
guideline-indicated device
8
device type
8
patients
7
mortality
6
crt-d
5
icd
5
mortality analysis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!