A rapid, automated system for the separation, preconcentration and measurement of Sr, and U, Am and Pu isotopes.

Talanta

School of the Environment and Water Quality Center, Trent University, 1600 West Bank Drive, Peterborough, Ontario, K9L 0G2, Canada.

Published: October 2021

An online separation and preconcentration method, using an automated flow injection setup and solid phase extraction followed by ICP-MS/MS, was developed for the analysis of Sr, and U, Am and Pu isotopes in various liquid sample matrices. The radionuclide analytes were separated from interferences and complex matrices using DGA-branched resin and Sr resin, then specific gases were used in the reaction/collision cell in the ICP-MS/MS to measure the different analytes. The system requires smaller sample volumes (10 mL), less sample preparation and shorter processing time (46 min per sample) compared to traditional radiometric and other MS techniques. Based on a 10 mL sample, the limits of detection were 1.48 pg L (8257 mBq L) for Sr, 1.75 pg L (0.40 mBq L) for U, 0.65 pg L (77.65 mBq L) for Am, and 0.56 pg L (1.25 mBq L) for Pu when all target analytes were measured in one analysis. The analytical figures of merit were evaluated for a range of sample matrices including lake water, seawater and urine and were comparable to those reported in the literature. This online system thus provides a novel, fully automated analytical tool with faster analysis time, smaller sample requirements, minimum sample preparation, low detection limits and the flexibility to handle single and multiple measurements of various radionuclides.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2021.122507DOI Listing

Publication Analysis

Top Keywords

separation preconcentration
8
sample
8
sample matrices
8
smaller sample
8
10 ml sample
8
sample preparation
8
rapid automated
4
automated system
4
system separation
4
preconcentration measurement
4

Similar Publications

In the present study, dispersive solid phase extraction - hydride generation integrated with micro-sampling gas-liquid separator - flame atomic absorption spectrometry was proposed to determine lead in lake water samples taken in the Horseshoe Island, Antarctica. In scope of this study, microwave assisted NiFeO nanoparticles were synthesized, and the characterization of nanoparticles were carried out by FT-IR, XRD and SEM. All influential parameters of dispersive solid phase extraction and hydride generation were optimized to enhance signal intensity belonging to the analyte.

View Article and Find Full Text PDF

Advancements in food technology have increased the need for thorough analysis to ensure food safety, quality, and compliance with regulatory requirements. Capillary electrophoresis-mass spectrometry (CE-MS) has emerged as a powerful tool in food analysis due to its high separation efficiency, low sample consumption, and ability to handle complex matrices. However, challenges such as the use of volatile running buffers and maintaining the stability of the electrical circuit connecting the CE and MS systems have been addressed through advancements in interface designs, such as sheathless systems and optimized sheath-liquid compositions.

View Article and Find Full Text PDF

Highly parallel simulation tool for the design of isotachophoresis experiments.

Anal Chim Acta

February 2025

Department of Mechanical Engineering, Stanford University, 488 Escondido Mall, Stanford, CA, 94305, USA. Electronic address:

Background: Isotachophoresis (ITP) is a well-established electrokinetic method for separation and preconcentration of analytes. Several simulation tools for ITP have been published, but their use for experimental design is limited by the computational time for a single run and/or by the number of conditions that can be investigated per simulation run. A large fraction of the existing solvers also do not account for ionic strength effects, which can influence whether an analyte focuses in ITP.

View Article and Find Full Text PDF

Biomass harvesting represents one of the main bottlenecks in microalgae large-scale production. Solid-liquid separation of the biomass accounts for 30% of the total production costs, which can be reduced by the use of flocculants as a pre-concentration step in the downstream process. The natural polymer chitosan and the two chemical flocculants FeCl and AlCl were tested on freshwater and two marine algae, and .

View Article and Find Full Text PDF

Exhaled breath contains trace levels of volatile organic compounds (VOCs) that can reveal information about metabolic processes or pathogens in the body. These molecules can be used for medical diagnosis, but capturing and accurately measuring them is a significant challenge in chemical separations. A highly selective nanoporous sorbent can be used to capture target molecules from a breath sample and preconcentrate them for use in a detector.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!