Pulmonary respiratory motion artifacts are common in four-dimensional computed tomography (4DCT) of lungs and are caused by missing, duplicated, and misaligned image data. This paper presents a geodesic density regression (GDR) algorithm to correct motion artifacts in 4DCT by correcting artifacts in one breathing phase with artifact-free data from corresponding regions of other breathing phases. The GDR algorithm estimates an artifact-free lung template image and a smooth, dense, 4D (space plus time) vector field that deforms the template image to each breathing phase to produce an artifact-free 4DCT scan. Correspondences are estimated by accounting for the local tissue density change associated with air entering and leaving the lungs, and using binary artifact masks to exclude regions with artifacts from image regression. The artifact-free lung template image is generated by mapping the artifact-free regions of each phase volume to a common reference coordinate system using the estimated correspondences and then averaging. This procedure generates a fixed view of the lung with an improved signal-to-noise ratio. The GDR algorithm was evaluated and compared to a state-of-the-art geodesic intensity regression (GIR) algorithm using simulated CT time-series and 4DCT scans with clinically observed motion artifacts. The simulation shows that the GDR algorithm has achieved significantly more accurate Jacobian images and sharper template images, and is less sensitive to data dropout than the GIR algorithm. We also demonstrate that the GDR algorithm is more effective than the GIR algorithm for removing clinically observed motion artifacts in treatment planning 4DCT scans. Our code is freely available at https://github.com/Wei-Shao-Reg/GDR.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8466681 | PMC |
http://dx.doi.org/10.1016/j.media.2021.102140 | DOI Listing |
In the early stages of atrial fibrillation (AF), most cases are paroxysmal (pAF), making identification only possible with continuous and prolonged monitoring. With the advent of wearables, smartwatches equipped with photoplethysmographic (PPG) sensors are an ideal approach for continuous monitoring of pAF. There have been numerous studies demonstrating successful capture of pAF events, especially using deep learning.
View Article and Find Full Text PDFComput Methods Programs Biomed
December 2024
Computer Science and Engineering, Northeastern University, Shenyang, China; Key Laboratory of Intelligent Computing in Medical Image, Ministry of Education, Northeastern University, Shenyang, China; National Frontiers Science Center for Industrial Intelligence and Systems Optimization, Shenyang, China.
Background And Objective: Left ventricular myocardium segmentation is of great significance for clinical diagnosis, treatment, and prognosis. However, myocardium segmentation is challenging as the medical image quality is disturbed by various factors such as motion, artifacts, and noise. Its accuracy largely depends on the accurate identification of edges and structures.
View Article and Find Full Text PDFMagn Reson Imaging
December 2024
Department of Radiology, Iwate Medical University, Yahaba, Japan.
Objective: The total examination time can be reduced if high-quality two-dimensional (2D) cine images can be collected post-contrast to minimize non-scanning time prior to late gadolinium-enhanced imaging. This study aimed to assess the equivalency of the pre-and post-contrast performance of 2D deep learning-based highly accelerated cardiac cine (DL cine) imaging by evaluating the image quality and the quantification of biventricular volumes and function in the clinical setting.
Material And Methods: Thirty patients (20 men, mean age 53.
Comput Med Imaging Graph
December 2024
Center for Advanced Medical Computing and Analysis, Massachusetts General Hospital and Harvard Medical School, Boston, United States. Electronic address:
Portable head CT images often suffer motion artifacts due to the prolonged scanning time and critically ill patients who are unable to hold still. Image-domain motion correction is attractive for this application as it does not require CT projection data. This paper describes and evaluates a generative model based on conditional diffusion to correct motion artifacts in portable head CT scans.
View Article and Find Full Text PDFJ Med Imaging (Bellingham)
January 2025
Siemens Healthineers AG, Forchheim, Germany.
Purpose: Digital breast tomosynthesis (DBT) has been introduced more than a decade ago. Studies have shown higher breast cancer detection rates and lower recall rates, and it has become an established imaging method in diagnostic settings. However, full-field digital mammography (FFDM) remains the most common imaging modality for screening in many countries, as it delivers high-resolution planar images of the breast.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!