Objectives: Hypoglossal nerve stimulation is an effective treatment option for obstructive sleep apnea (OSA) in positive airway pressure therapy failure. Nonetheless, data regarding the functional effect of modifying stimulation parameters within each electrode configuration are limited.
Materials And Methods: In a retrospective study of 76 patients with 12 months or more follow-up, functional tongue protrusion thresholds were compared for pulse width and frequency configurations of 90 μsec 33 Hz vs 120 μsec 40 Hz. The number of tolerated voltage amplitude steps between sensation, functional, and subdiscomfort thresholds were assessed for both settings as well as impedances.
Results: The overall cohort showed improvement in OSA metrics: median apnea-hypopnea index from 30.0/hour to 18.6/hour and Epworth Sleepiness Scale from 13.5 to 7.6. For both bipolar and unipolar electrode configurations, the stimulation amplitude required for functional tongue protrusion was significantly reduced when the pulse width and frequency were converted from 90 μsec 33 Hz to 120 μsec 40 Hz (p < 0.001). Nevertheless, the number of voltage amplitude steps from sensation, functional, to subdiscomfort thresholds did not differ between the two settings. The ratio of automatically derived impedances between bipolar and unipolar electrode configurations was relevantly correlated with the ratio of functional thresholds at these parameters.
Conclusion: Changing the stimulation parameters may lower the voltage requirements while maintaining the same effect on tongue protrusion. Changing these stimulation parameters does not affect the range of tolerated impulse steps between functional and subdiscomfort thresholds. Future technical appliances could help estimate functional thresholds at different electrode configurations for each patient by automatically measuring impedances.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/ner.13490 | DOI Listing |
Sci Rep
January 2025
Department of Electrical Engineering, College of Engineering, King Khalid University, P.O. Box 394, Abha, 61421, KSA, Saudi Arabia.
In wind energy generation systems, ensuring high energy quality is critical but is often compromised due to the limited performance and durability of conventional regulators. To address this, this work presents a novel controller for managing the machine-side inverter of a single-rotor large wind turbine system using an induction machine-type generator. The proposed controller is designed using proportional, integral, and derivative error-based mechanisms, which fundamentally differ from traditional proportional-integral (PI) regulators.
View Article and Find Full Text PDFMaterials (Basel)
January 2025
School of Mechatronic Engineering and Automation, Shanghai University, Shanghai 200444, China.
Recently, ultrafast laser direct writing has become an effective method for preparing flexible films with micro-nano structures. However, effective control of laser parameters to obtain acceptable micro-nano structures and the effect of micro-nano structure sizes on function of the film remain challenges. Additionally, flexible films with high X-band transmittance are urgently required in aerospace and other fields.
View Article and Find Full Text PDFProc Natl Acad Sci U S A
January 2025
Faculty of Technical Chemistry, Institute of Chemical Technologies and Analytics, Technische Universität Wien, Vienna 1060, Austria.
Atomic force microscopy-infrared spectroscopy (AFM-IR) is a photothermal scanning probe technique that combines nanoscale spatial resolution with the chemical analysis capability of mid-infrared spectroscopy. Using this hybrid technique, chemical identification down to the single molecule level has been demonstrated. However, the mechanism at the heart of AFM-IR, the transduction of local photothermal heating to cantilever deflection, is still not fully understood.
View Article and Find Full Text PDFCirc Arrhythm Electrophysiol
January 2025
Biosense Webster, Inc, Irvine, CA (J.M., T.S., S.F.-H.).
Background: Sequential application of radiofrequency with pulsed field (PF) ablation may increase lesion depth while preserving the advantages of PF. The study's aim was to determine lesion dimensions of sequential, colocalized radiofrequency and PF ablation.
Methods: A preclinical study using swine (n=4) performed lesions in the right/left ventricles.
Nanoscale Horiz
January 2025
London Centre for Nanotechnology, 19 Gordon St, London, WC1H 0AH, UK.
We demonstrate low energy, forming and compliance-free operation of a resistive memory obtained by the partial oxidation of a two-dimensional layered van-der-Waals semiconductor: hafnium disulfide (HfS). Semiconductor-oxide heterostructures are achieved by low temperature (<300 °C) thermal oxidation of HfS under dry conditions, carefully controlling process parameters. The resulting HfOS/HfS heterostructures are integrated between metal contacts, forming vertical crossbar devices.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!