A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Hologic Aptima SARS-CoV-2 assay enables high ratio pooling saving reagents and improving turnaround time. | LitMetric

Background: The Hologic Aptima™ TMA SARS-CoV-2 assay was employed to test pooled nasopharyngeal (NP) samples to evaluate the performance of pooled sample testing and characterize variables influencing results.

Methods: Results on 1033 previously tested NP samples were retrieved to characterize the relative light units (RLU) of SARS-CoV-2-positive samples in the tested population. The pooling strategy of combining 10 SARS-CoV-2 samples into one pool (10/1) was used in this study. The results were compared with neat sample testing using the same Aptima™ TMA SARS-CoV-2 assay and also the CDC RT-PCR and the Cepheid SARS-CoV-2 assays.

Results: The Aptima assay compares favorably with both CDC RT-PCR and the Cepheid SARS-CoV-2 assays. Once samples are pooled 10 to 1 as in our experiments, the resulting signal strength of the assay suffers. A divide opens between pools assembled from strong-positive versus only weak-positive samples. Pools of the former can be reliably detected with positive percent agreement (PPA) of 95.2%, while pools of the latter are frequently misclassified as negative with PPA of 40%. When the weak-positive samples with kRLU value lower than 1012 constitute 3.4% of the total sample profile, the assay PPA approaches 93.4% suggesting that 10/1 pooled sample testing by the Aptima assay is an effective screening tool for SARS-CoV-2.

Conclusion: Performing pooled testing, one should monitor the weak positives with kRLU lower than 1012 or quantification cycle (Cq) value higher than 35 on an ongoing basis and adjust pooling approaches to avoid reporting false negatives.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8418467PMC
http://dx.doi.org/10.1002/jcla.23888DOI Listing

Publication Analysis

Top Keywords

sars-cov-2 assay
12
sample testing
12
aptima™ tma
8
tma sars-cov-2
8
pooled sample
8
cdc rt-pcr
8
rt-pcr cepheid
8
cepheid sars-cov-2
8
aptima assay
8
weak-positive samples
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!