A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Perimembranous ventricular septal defect closure via ultra-minimal trans intercostal incision in children. | LitMetric

Aims: This study aimed to investigate the safety, feasibility and, availability of perimembranous ventricular septal defect (PmVSD) closure via a left parasternal ultra-minimal trans intercostal incision in children.

Methods And Results: From January 2015 to January 2019, 131 children with restrictive PmVSDs were enrolled in this study and successfully done in 126 patients (96.18%). PmVSDs were occluded via an ultra-minimal trans intercostal incision (≤1 cm), and the entire occlusive process was guided and monitored by TEE. A pericardium hanging technique was employed without sternal incision. PmVSDs were closed through a short delivery sheath assembled using a concentric occluder device. All patients were followed up for a period ranging from18 months to 24 months. Thirteen patients with PmVSD had aneurysm of membranous septum (AMS). Multistream (≥2) PmVSDs with AMS were found in 11 cases. After the operation, mild residual shunt beside the amplatzer occluder in one patient was found and had self-healing result during the 5-month follow-up period. Five patients transferred to ventricular septal defect repair operation under direct visualization with a cardiopulmonary bypass. One reason was ventricular fibrillation when guidewire passed the PmVSD, another was device dislocation, and others were the guidewire cannot pass through the PmVSD.

Conclusions: PmVSDs closure using a concentric occluder via a left parasternal ultra-minimal trans intercostal incision under TEE guidance is feasible, safe, and effective in children. This approach can be considered as an alternative treatment to open-heart surgery for restrictive PmVSDs.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jocs.15760DOI Listing

Publication Analysis

Top Keywords

ultra-minimal trans
16
trans intercostal
16
intercostal incision
16
ventricular septal
12
septal defect
12
perimembranous ventricular
8
left parasternal
8
parasternal ultra-minimal
8
restrictive pmvsds
8
concentric occluder
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!