Leadless atrioventricular synchronous pacing: a validation pilot study with Holter monitoring.

Rev Esp Cardiol (Engl Ed)

Servicio de Cardiología, Hospital Universitario Infanta Leonor, Madrid, Spain; Departamento de Medicina, Universidad Complutense de Madrid, Madrid, Spain.

Published: November 2021

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.rec.2021.06.004DOI Listing

Publication Analysis

Top Keywords

leadless atrioventricular
4
atrioventricular synchronous
4
synchronous pacing
4
pacing validation
4
validation pilot
4
pilot study
4
study holter
4
holter monitoring
4
leadless
1
synchronous
1

Similar Publications

Unlabelled: Corrected transposition of the great arteries (c-TGA) is a congenital abnormality characterized by atrioventricular (AV) and ventriculoarterial discordance, associated with early and late-onset conduction disturbances. We report the case of a c-TGA patient affected by congenital complete AV block, with right ventricular lead malfunction with prolonged dwell time and two abandoned leads. He underwent leadless VDD pacemaker implantation at an unusual site (i.

View Article and Find Full Text PDF

Modular Leadless Pacing: A Case Series of Leadless Pacemaker Upgrades.

JACC Clin Electrophysiol

December 2024

Division of Cardiology, Department of Medicine, Weill Cornell Medicine, New York-Presbyterian Hospital, New York, New York, USA. Electronic address:

View Article and Find Full Text PDF

A 21-year-old man, known case of the repaired congenital heart disease, developed complete atrioventricular block (AVB) one week after simultaneous bioprosthetic pulmonary and tricuspid valve replacement and atrial septal defect repair. Considering the persistence of the AVB, it was decided to implant a permanent pacemaker. After considering all available options and the issues related to the patient, it was decided to implant a leadless pacemaker (LLP).

View Article and Find Full Text PDF

Minimizing for Maximum Benefit: An Illustrative Case-Series of Atrial Only Leadless Pacing.

Pacing Clin Electrophysiol

January 2025

Division of Cardiology, Department of Medicine, Weill Cornell Medicine, New York Presbyterian Hospital, New York, USA.

Leadless pacing technology now includesdedicated atrial helix-fixation leadless pacemakers (LPs), expanding theapplication of leadless devices for patients with sinus node dysfunction andatrioventricular block during sinus rhythm. This first reportedcase-series of atrial LPs describes and discusses the potential use-casescenarios of recently approved helix-fixation atrial LPs. The article highlights important concepts regarding their use, including implantationtechniques, programming, battery conservation, and the low rate of progressionof AV block in patients implanted with AAI(R) pacemakers.

View Article and Find Full Text PDF

Cardiac Implantable Electronic Devices in Cardiac Transplant Patients: A Comprehensive Review.

Cardiol Rev

November 2024

Department of Cardiovascular Medicine, Cardiovascular Analytics Group, Islamabad, Pakistan.

A fraction of patients (approximately 10%) undergoing heart transplantation require permanent pacemaker (PPM) implantation due to sinus node dysfunction or atrioventricular block, occurring either shortly after surgery or later. The incidence of PPM implantation has declined to less than 5% with the introduction of bicaval anastomosis transplantation surgery. Pacing dependency during follow-up varies among recipients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!