An alignment-free sensing module for the positioning system based on tunneling magnetoresistive (TMR) sensors with an absolute-incremental-integrated scale is demonstrated. The sensors of the proposed system for both lines consist of identical layer stacks; therefore, all sensors can be fabricated in identical processes from thin film deposition to device patterning on a single substrate. Consequently, the relative position of the sensors can be predefined at the lithography stage and the alignment error between sensors caused by the manual installation is completely eliminated. Different from the existing sensing scheme for incremental lines, we proposed to utilize the magnetic tunnel junctions with a perpendicular anisotropy reference layer and an in-plane anisotropy sensing layer. The sensors are placed parallel to the scale plane with magnetization of the sensing layer in the plane, which show the capability of polarity detection for the absolute line and reveal sinusoidal output signal for the incremental line. Furthermore, due to the large signal of TMR, the working distance can be further improved compared with conventional sensors. In addition, the cost of the positioning system is expected to be lowered, since all the sensors are fabricated in the same process without extra installation. Our design may pave a new avenue for the positioning system based on a magnetic detection scheme.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8233855 | PMC |
http://dx.doi.org/10.3390/s21124137 | DOI Listing |
Cell Commun Signal
January 2025
Department of Oncological Sciences, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, New York, NY, 10029, USA.
One hallmark of cancer is the upregulation and dependency on glucose metabolism to fuel macromolecule biosynthesis and rapid proliferation. Despite significant pre-clinical effort to exploit this pathway, additional mechanistic insights are necessary to prioritize the diversity of metabolic adaptations upon acute loss of glucose metabolism. Here, we investigated a potent small molecule inhibitor to Class I glucose transporters, KL-11743, using glycolytic leukemia cell lines and patient-based model systems.
View Article and Find Full Text PDFSci Rep
January 2025
Zhongyuan University of Technology, Zhengzhou, 450007, China.
This paper studies the practical prescribed-time control problem for dual-arm robots handling an object with output constraints. Firstly, by utilizing the property that the sum of internal forces in the grasping space is zero, the system model is obtained and decomposed into the contact force model and free motion model, which are orthogonal to each other. Furthermore, by combining the performance function and constraint function, the original system tracking error is transformed to a new one, whose boundedness can ensure that the original system variable converges to the predetermined range within the specified time.
View Article and Find Full Text PDFSci Rep
January 2025
Mallinckrodt Institute of Radiology, Washington University School of Medicine, 4515 McKinley Ave., St. Louis, MO, 63110, USA.
Functional magnetic resonance imaging (fMRI) has dramatically advanced non-invasive human brain mapping and decoding. Functional near-infrared spectroscopy (fNIRS) and high-density diffuse optical tomography (HD-DOT) non-invasively measure blood oxygen fluctuations related to brain activity, like fMRI, at the brain surface, using more-lightweight equipment that circumvents ergonomic and logistical limitations of fMRI. HD-DOT grids have smaller inter-optode spacing (~ 13 mm) than sparse fNIRS (~ 30 mm) and therefore provide higher image quality, with spatial resolution ~ 1/2 that of fMRI, when using the several source-detector distances (13-40 mm) afforded by the HD-DOT grid.
View Article and Find Full Text PDFJ Shoulder Elbow Surg
January 2025
Roth | McFarlane Hand & Upper Limb Center, St Joseph's Health Care London, London, ON, Canada.
Background: Precise and accurate glenoid preparation is important for the success of shoulder arthroplasty. Despite advancements in preoperative planning software and enabling technologies, most surgeons execute the procedure manually. Patient-specific instrumentation (PSI) facilitates accurate glenoid guide pin placement for cannulated reaming; however, few commercially available systems offer depth of reaming control.
View Article and Find Full Text PDFLancet Neurol
February 2025
European Medicines Agency, 1083 HS Amsterdam, Netherlands.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!