Asymptomatic/mildly symptomatic coronavirus disease 2019 (COVID-19) patients produce a considerable amount of virus and transmit severe acute respiratory syndrome virus 2 (SARS-CoV-2) through close contact. Preventing in-hospital transmission of SARS-CoV-2 is challenging, since symptom-based screening protocols may miss asymptomatic/mildly symptomatic patients. In particular, dental healthcare workers (HCWs) are at high risk of exposure, as face-to-face contact and exposure to oral secretions is unavoidable. We report exposure of HCWs during dental procedures on a mild symptomatic COVID-19 patient. A 32-year-old male visited a dental clinic at a tertiary care hospital. He experienced mild cough, which started three days before the dental visit, but did not report his symptom during the entrance screening. He underwent several dental procedures and imaging for orthognathic surgery without wearing a mask. Seven HCWs were closely exposed to the patient during dental procedures that could have generated droplets and aerosols. One HCW had close contact with the patient during radiologic exams, and seven HCWs had casual contact. All HCWs wore particulate filtering respirators with 94% filter capacity and gloves, but none wore eye protection or gowns. The next day, the patient experienced dysgeusia and was diagnosed with COVID-19 with high viral load. All HCWs who had close contact with the patient were quarantined for 14 days, and polymerase chain reaction and antibody tests for SARS-CoV-2 were negative. This exposure event suggests the protective effect of particulate filtering respirators in dental clinics. The recommendations of different levels of personal protective equipment (PPE) for dental HCWs according to the procedure types should be established according to the planned procedure, the risk of COVID-19 infection of the patient, and the outbreak situation of the community.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8297396PMC
http://dx.doi.org/10.3390/ijerph18126481DOI Listing

Publication Analysis

Top Keywords

particulate filtering
12
filtering respirators
12
close contact
12
dental procedures
12
dental
9
dental clinic
8
healthcare workers
8
asymptomatic/mildly symptomatic
8
contact patient
8
hcws
7

Similar Publications

Air pollution, particularly fine particulate matter (PM2.5), is a global health issue affecting millions. In southern Chile, firewood used for heating exacerbates pollution, especially in winter.

View Article and Find Full Text PDF

Structural firefighters are exposed to an array of polycyclic aromatic hydrocarbons (PAHs) as a result of incomplete combustion of both synthetic and natural materials. PAHs are found in both the particulate and vapor phases in the firefighting environment and are significantly associated with acute and chronic diseases, including cancer. Using a fireground exposure simulator (FES) and standing mannequins dressed in four different firefighter personal protective equipment (PPE) conditions, each with varying levels of protective hood interface and particulate-blocking features, the efficacy of the hoods was assessed against the ingress of PAHs (specifically, naphthalene).

View Article and Find Full Text PDF

This study aimed to test the use of Rietveld refinement on respirable aerosol samples to determine the phase of respirable crystalline silica (RCS) and other minerals. The results from the Rietveld refinement were compared to an external standard method and gravimetrical measurements. Laboratory samples consisting of α-quartz, feldspar, and calcite with variable proportions and total mass loadings were made and analyzed using the NIOSH 7500 , followed by Rietveld refinement.

View Article and Find Full Text PDF

Novel perspective on particulate matter and Alzheimer's disease: insights from adverse outcome pathway framework.

Environ Pollut

January 2025

Joint International Research Laboratory of Environment and Health, Ministry of Education, Guangdong Provincial Engineering Technology Research Center of Environmental Pollution and Health Risk Assessment, Department of Occupational and Environmental Health, School of Public Health, Sun Yat-sen University, Guangzhou 510080, China. Electronic address:

Alzheimer's disease (AD) is a neurodegenerative disease, that accounts for 50-75% of all dementia cases. Evidence demonstrates the link between particulate matter (PM) exposure and AD. However, there are still considerable research gaps.

View Article and Find Full Text PDF

Ammonia is a highly promising carbon-neutral fuel. The use of ammonia as a fuel for internal combustion engines can reduce fossil energy consumption and greenhouse gas emissions. However, the high ignition energy required for ammonia and the slow flame propagation rate result in low combustion efficiency when ammonia is used directly in internal combustion engines.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!