A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simultaneous Quantification of Ampicillin and Kanamycin in Water Samples Based on Lateral Flow Aptasensor Strip with an Internal Line. | LitMetric

Simultaneous Quantification of Ampicillin and Kanamycin in Water Samples Based on Lateral Flow Aptasensor Strip with an Internal Line.

Molecules

Department of Chemical Engineering & Pharmaceutical Engineering, College of Chemical Engineering, Huaqiao University, Xiamen 361021, China.

Published: June 2021

AI Article Synopsis

  • A new rapid detection method using a lateral flow assay (LFA) has been developed to quantitatively detect two antibiotics: ampicillin (AMP) and kanamycin (KAM).
  • An internal system was created to minimize non-specific adsorption, utilizing a non-specific DNA as an internal standard recognized by a DNA marker.
  • The method demonstrates high accuracy with dynamic detection ranges and limits of quantification for both antibiotics and has been successfully applied to analyze various water sources for environmental monitoring.

Article Abstract

In this work, a simple and rapid method based on the lateral flow assay (LFA) has been developed for the detection of dual antibiotics. To achieve the quantitative assay and to reduce the non-specific adsorption, an internal system has been developed. A non-specific DNA was exploited as an internal standard and could be recognized by the DNA marker that was coated at the internal line. Two different kinds of aptamers were applied to recognize ampicillin (AMP) and kanamycin (KAM), and the distance between the detection line and conjugate pad was then optimized. Under the optimum conditions, the quantitative assays of AMP (R = 0.984) and KAM (R = 0.990) were achieved with dynamic ranges of 0.50 to 500.0 ng/L, and of 0.50 to 1000.0 ng/L, respectively. The LOQs of AMP and KAM were 0.06 ng/L and 0.015 ng/L, respectively. Finally, the proposed method has been successfully applied to analyze aquaculture water, tap water, and lake water, and hospital wastewater, indicating the established method could be used to monitor the environment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8270245PMC
http://dx.doi.org/10.3390/molecules26133806DOI Listing

Publication Analysis

Top Keywords

based lateral
8
lateral flow
8
simultaneous quantification
4
quantification ampicillin
4
ampicillin kanamycin
4
water
4
kanamycin water
4
water samples
4
samples based
4
flow aptasensor
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!