The aim of this study was to model and evaluate the Specific Energy Absorption Rate (SAR) values in humans in proximity to fixed multi-antenna I-RFID readers of passive tags under various scenarios mimicking exposure when they are incorporated in Real-Time Location Systems (RTLS), or used to monitor Personal Protective Equipment (PPE). The sources of the electromagnetic field (EMF) in the modelled readers were rectangular microstrip antennas at a resonance frequency in free space of 866 MHz from the ultra-high frequency (UHF) RFID frequency range of 865-868 MHz. The obtained results of numerical modelling showed that the SAR values in the body 5 cm away from the UHF RFID readers need consideration with respect to exposure limits set by international guidelines to prevent adverse thermal effects of exposure to EMF: when the effective radiated power exceeds 5.5 W with respect to the general public/unrestricted environments exposure limits, and with respect to occupational/restricted environments exposure limits, when the effective radiated power exceeds 27.5 W.