: Direct current cardioversion (DCCV) is a safe and useful treatment for atrial tachyarrhythmias. In the past, the energy delivered in DCCV was decided upon empirically, based only on the type of tachyarrhythmia. This conventional method does not consider individual factors and may lead to unnecessary electrical damage. : We performed DCCV in patients with atrial tachyarrhythmias. The impedance and electrical current at the moment of shock were measured. The human thoracic impedance between both defibrillator patches and the electric current that was used were measured. : A total of 683 DCCVs were performed on 466 atrial tachyarrhythmia patients. The average impedance was 64 ± 11 Ω and the average successful current was 23 ± 6 mA. The magnitude of the electrical current that was successful depended upon the human impedance (linear regression, B = -0.266, < 0.001) and the left atrial diameter (B = 0.092, < 0.001). Impedance was directly proportional to body mass index (BMI) (B = 1.598, < 0.001) and was higher in females than in males (77 ± 15 Ω vs. 63 ± 11 Ω, < 0.001). Notably, the high-impedance (>70 Ω) group had a higher BMI (27 ± 4 kg/m vs. 25 ± 3 kg/m, < 0.001) and a higher proportion of females (37% vs. 9%, < 0.001) than the low-impedance group (<70 Ω). However, thoracic impedance was not an independent predictor for successful DCCV. : Human thoracic impedance was one of the factors that impacted the level of electrical current required for successful DCCV in patients with atrial arrhythmias. In the future, it will be helpful to consider individual predictors, such as BMI and gender, to minimize electrical damage during DCCV.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8231855PMC
http://dx.doi.org/10.3390/medicina57060618DOI Listing

Publication Analysis

Top Keywords

thoracic impedance
8
impedance electrical
8
patients atrial
8
atrial tachyarrhythmias
8
electrical current
8
0001 higher
8
impedance
6
0001
6
atrial
5
current
5

Similar Publications

Cardiac implantable electronic devices and their integrated thoracic impedance sensors have been used to detect sleep apnea for over a decade now. Despite their usage in daily clinical practice, there are only limited data on their diagnostic accuracy. AIRLESS and UPGRADE were prospective investigator-driven trials meant to validate the AP scan (Boston Scientific, Marlborough, MA, USA) in heart failure cohorts.

View Article and Find Full Text PDF

Daily Measurements from Cardiac Implantable Electronic Devices to Assess Health Status.

Diagnostics (Basel)

December 2024

Department of Cardiology, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.

Cardiac implantable electronic devices (CIEDs) such as pacemakers and implantable cardioverter-defibrillators (ICDs) are increasingly used in the aging population. Modern CIEDs perform daily measurements, mainly aimed at discovering early signs of battery depletion or electrode dysfunction. Changes in thresholds, intracardiac signals, and pacing impedances can be caused by exacerbation of existing conditions or novel clinical problems.

View Article and Find Full Text PDF

This study aims to assess the outcomes of therapeutic options for aortic arch pathologies by comparing thoracic endovascular aortic repair (TEVAR) with open arch replacement (OAR) using woven polyester grafts from a mechanical and biomechanical perspective, with emphasis on ex vivo perfused human thoracic aortas reproducing heart rate and stroke volume conditions. Eleven non-diseased thoracic aortas from human cadavers were divided into TEVAR (n=5) and OAR (n=6) and tested using a custom-built mock circulation loop. Pressure, diameter, and stroke volume were monitored during perfusion before and after the intervention.

View Article and Find Full Text PDF

Background: Lung cancer is a pathology with an important incidence. It is a multifactorial disease characterized by epigenetic and nutritional factors. Indeed, there is a strong association between adipose tissue and the pulmonary system, and low-grade inflammation of obese and/or overweight subjects have a pivotal role in lung cancer establishment.

View Article and Find Full Text PDF

Patients with fatty acid oxidation disorders (FAODs) experience muscle symptoms due to impaired ATP metabolism and the toxicity of accumulated mitochondrial FAO substrates or intermediates, especially during catabolic states. A major issue is the absence of specific and sensible biomarkers to evaluate metabolic equilibrium. The relationship between cardiac output (Q) and oxygen consumption (VO) during incremental exercise (dQ/dVO) provides an indirect surrogate of mitochondrial function.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!