Eye tracking techniques based on deep learning are rapidly spreading in a wide variety of application fields. With this study, we want to exploit the potentiality of eye tracking techniques in ocular proton therapy (OPT) applications. We implemented a fully automatic approach based on two-stage convolutional neural networks (CNNs): the first stage roughly identifies the eye position and the second one performs a fine iris and pupil detection. We selected 707 video frames recorded during clinical operations during OPT treatments performed at our institute. 650 frames were used for training and 57 for a blind test. The estimations of iris and pupil were evaluated against the manual labelled contours delineated by a clinical operator. For iris and pupil predictions, Dice coefficient (median = 0.94 and 0.97), Szymkiewicz-Simpson coefficient (median = 0.97 and 0.98), Intersection over Union coefficient (median = 0.88 and 0.94) and Hausdorff distance (median = 11.6 and 5.0 (pixels)) were quantified. Iris and pupil regions were found to be comparable to the manually labelled ground truths. Our proposed framework could provide an automatic approach to quantitatively evaluating pupil and iris misalignments, and it could be used as an additional support tool for clinical activity, without impacting in any way with the consolidated routine.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8271684PMC
http://dx.doi.org/10.3390/s21134400DOI Listing

Publication Analysis

Top Keywords

iris pupil
16
coefficient median
12
convolutional neural
8
neural networks
8
pupil iris
8
ocular proton
8
proton therapy
8
eye tracking
8
tracking techniques
8
automatic approach
8

Similar Publications

Optimal frequency bands for pupillography for maximal correlation with HRV.

Sci Rep

January 2025

Centre for Informatics and Systems of the University of Coimbra, Department of Informatics Engineering, University of Coimbra, Coimbra, Portugal.

Assessing cognitive load using pupillography frequency features presents a persistent challenge due to the lack of consensus on optimal frequency limits. This study aims to address this challenge by exploring pupillography frequency bands and seeking clarity in defining the most effective ranges for cognitive load assessment. From a controlled experiment involving 21 programmers performing software bug inspection, our study pinpoints the optimal low-frequency (0.

View Article and Find Full Text PDF

Approximately 3% of individuals in road traffic accidents suffer ocular injuries. We present a case of a man in his late 80s who presented with bilateral corneal decompensation following airbag deployment during a road traffic accident. Ocular examination revealed multilevel ocular injury with severe bilateral corneal oedema.

View Article and Find Full Text PDF

Background: The performance of quantitative pupillary light reflex (qPLR) and the neurological pupil index (NPi) was used to predict neurological outcomes in cardiac arrest (CA) patients.

Methods: Eligible studies on the ability of the qPLR and NPi to predict neurological outcomes in CA patients were searched from the PubMed and China National Knowledge Infrastructure databases until July 2023. The pooled odds ratio (OR) and its 95% confidence interval (95% CI), area under the curve, sensitivity analysis, and publication bias were analyzed via Stata 14.

View Article and Find Full Text PDF

Purpose: Using a fully automated multitask deep learning method, which enabled simultaneous segmentation and quantification of all major anterior segment structures with swept-source optical coherence tomography (SS-OCT), we aimed to investigate the three-dimensional (3D) alterations in iris morphology before and after implantable collamer lens (ICL) surgery.

Methods: All enrolled patients underwent anterior segment SS-OCT (ANTERION) within one week before and after ICL surgery. A multitask network automatically performed iris SS-OCT image segmentation and quantitative measurements of 3D iris morphology (iris thickness and volume of the inner 1-mm annular area and the outer 1-2-mm annular area, iris curvature [I-Curve], and iris smooth index [SI]).

View Article and Find Full Text PDF

Pupil responds spontaneously to visuospatial regularity.

J Vis

January 2025

Department of Psychology, Hangzhou Normal University, Hangzhou, Zhejiang, China.

Beyond the light reflex, the pupil responds to various high-level cognitive processes. Multiple statistical regularities of stimuli have been found to modulate the pupillary response. However, most studies have used auditory or visual temporal sequences as stimuli, and it is unknown whether the pupil size is modulated by statistical regularity in the spatial arrangement of stimuli.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!