Introduction: Absorption of iodine through skin and an increased incidence of thyroid disorders due to iodophor exposure are reported. However, the risk of oral transmucosal absorption of povidone-iodine after intraoral preparation is not clear.

Objective: To investigate the possibility of oral transmucosal absorption of povidone-iodine after intraoral preparation and its effect on thyroxine level in blood.

Patients And Methods: A randomized controlled study was carried out in the department of oral and maxillofacial surgery. Twenty- to 40-year-old healthy male adults planning to receive oral surgery under general anesthesia were enrolled. The study group received povidone-iodine irrigation of oral cavity for 3 min as intraoral preparation before operation. The control group received chlorhexidine gluconate irrigation of oral cavity for 3 min as intraoral preparation before operation. Iodine levels in blood and urine, and thyroxine levels in blood were tested and compared, before and after operation.

Result(s): In total, 24 patients were included and analyzed finally. We found that after intraoral preparation with povidone-iodine, serum iodine level increased significantly to 2-3 times the pre-operation level in 15-30 min, and the urinary iodine level increased to 5 times the pre-operation level on the first day after operation. Iodine levels in blood and urine decreased significantly on the third day after operation but still significantly greater than the pre-operation levels. However, thyroxine levels were not altered accordingly.

Conclusion(s): Oral transmucosal absorption of iodine is observed when povidone-iodine is used for intraoral preparation in healthy male adults, though the free thyroxine in blood is not affected accordingly.

Clinical Relevance: Povidone-iodine is commonly used as an antiseptic in oral surgery and dental clinics. Based on our findings that iodine levels in blood and urine may elevate significantly after intraoral preparation with povidone-iodine prior to oral surgeries, care must be taken for individuals when excess iodine intakes can endanger the safety of the patient.

Registration Information: Name of the trial registry: The Chinese Clinical Trial Registry ( http://www.chictr.org.cn/ ). Registration number: ChiCTR2100042028.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00784-021-04048-7DOI Listing

Publication Analysis

Top Keywords

intraoral preparation
32
oral transmucosal
16
transmucosal absorption
16
levels blood
16
absorption iodine
12
preparation povidone-iodine
12
povidone-iodine intraoral
12
iodine levels
12
blood urine
12
oral
11

Similar Publications

Objective: To assess the state of endodontic practices and identify factors influencing the use of modern endodontic techniques among dental practitioners in Croatia.

Materials And Methods: A questionnaire was distributed to all dental offices in Croatia, yielding 819 responses (27% response rate). Data were descriptively analyzed and statistically modeled.

View Article and Find Full Text PDF

Background/purpose: The accuracy of intraoral scanners (IOSs) plays a crucial role in the success of final restorations in digital workflows. Previous studies have shown that numerous factors affect the accuracy of IOSs. Most studies have evaluated the accuracy of IOS under one restoration condition.

View Article and Find Full Text PDF

Effect of scan path on accuracy of complete arch intraoral scan.

J Adv Prosthodont

December 2024

Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea.

Purpose: This study aimed to compare the accuracy of an alternative scan path with that of traditional scan paths to obtain a more accurate method for complete arch scans.

Materials And Methods: A mandibular stone cast, including tooth preparations for the inlay, crown, and fixed prosthesis, was scanned 10 times using four different scan paths (A, B, C, and D). The scans were converted into stereolithography files, resized, and superimposed onto a control file obtained from a desktop scanner.

View Article and Find Full Text PDF

Dentistry is steadily evolving along the digital pathway at a constant and sure pace. Intraoral scanners (IOSs) started to enhance the precision and trueness of the restorations, making prosthodontics treatment more predictable. The objective of this study was to compare the trueness and internal fit of the printed provisional veneers for 60 preparations with three different types of finish lines.

View Article and Find Full Text PDF

Background And Objectives: The present study aims to assess and compare the accuracy of post-space impressions captured by three different intraoral scanners (IOS) using various canal diameters.

Methods: Three extracted natural maxillary central incisors were selected and prepared for a 1 mm wide margin and a 3 mm ferrule. All steps required for the endodontic procedure were performed, and the post space was prepared using post drills.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!