Purpose: To optimize a whole-brain magnetization transfer saturation (MT ) protocol at 7T, focusing on maximizing obtainable MT under the constraints of specific absorption rate (SAR) and transmit field inhomogeneity, while avoiding bias and keeping scan time short.
Theory And Methods: MT is a semi-quantitative metric, obtained by spoiled gradient-echo MRI in the imaging steady-state. Optimization was based on an established 7T dual flip angle protocol, and focused on MT pulse, readout flip angle, repetition time (TR), offset frequency (Δ), and correction of residual effects from transmit field inhomogeneities by separate flip angle mapping.
Results: A 100% SAR level was reached at a 180° MT pulse flip angle, using a compact sinc main lobe (4 ms duration) and minimum TR = 26.5 ms. The use of Δ = +2.0 kHz caused no discernible direct saturation, while Δ = -2.0 kHz resulted in 45% higher MT in white matter (WM) compared to Δ = +2.0 kHz. A 4° readout flip angle eliminated bias while yielding a good signal-to-noise ratio. Increased TR yielded only a little increase in MT , and TR = 26.5 ms (scan time 04:58 min) was thus selected. Post hoc transmit field correction clearly improved homogeneity, especially in WM.
Conclusions: The range of MT is limited at 7T, and this can partly be overcome by the exploitation of the asymmetry of the macromolecular lineshape through the sign of Δ. To reduce scan time, a compact MT pulse with a sufficiently narrow frequency response should be used. TR and readout flip angle should be kept short/small. Transmit field correction through separate flip angle mapping is required.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/mrm.28899 | DOI Listing |
Purpose: The depth within the body, small diameter, long length, and varying tissue surrounding the spinal cord impose specific considerations when designing radiofrequency coils. The optimal coil configuration for 7 T cervical spinal cord MRI is unknown and, currently, there are very few coil options. The purpose of this work was (1) to establish a quality control protocol for evaluating 7 T cervical spinal cord coils and (2) to use that protocol to evaluate the performance of 4 different coil designs.
View Article and Find Full Text PDFChildren (Basel)
January 2025
Pediatric Orthopedics, Deformity Reconstruction and Foot Surgery, University Hospital Muenster, 48149 Muenster, Germany.
: Legg-Calvé-Perthes disease (LCPD) presents challenges in treatment due to its varied course and unclear etiology. This study aimed to evaluate the efficacy of combining proximal femoral varus osteotomy (PFVO) with a modified trochanteric flip osteotomy to address biomechanical consequences and improve hip abductor muscle strength. : We present a modified approach combining PFVO with a trochanteric flip osteotomy.
View Article and Find Full Text PDFInvest Radiol
January 2025
From the Departments of Radiology (J.F.H., S.Y.C., J.-P.G., J.S., P.N., S.B.R., T.M.G.), Biomedical Engineering (S.B.R., T.M.G.), Medical Physics (S.Y.C., S.B.R., T.M.G.), Medicine (S.B.R.), and Emergency Medicine (S.B.R.), University of Wisconsin-Madison, WI; and Department of Diagnostic and Interventional Radiology (J.F.H., J.-P.G.), University Hospital Würzburg, Würzburg, Germany.
Rationale And Objectives: Pulmonary magnetic resonance angiography (MRA) is an imaging method with proven utility for the exclusion of pulmonary embolism and avoids the need for ionizing radiation and iodinated contrast agents. High-relaxivity gadolinium-based contrast agents (GBCAs), such as gadopiclenol, can be used to reduce the required gadolinium dose for pulmonary MRA. The aim of this study was to compare the contrast enhancement performance of gadopiclenol with an established gadobenate dimeglumine-enhanced pulmonary MRA protocol.
View Article and Find Full Text PDFMagn Reson Med
January 2025
Department of Radiology and Imaging Sciences, University of Utah Health, Salt Lake City, Utah, USA.
Purpose: The single reference variable flip angle sequence with a multi-echo stack of stars acquisition (SR-VFA-SoS) simultaneously measures temperature change using proton resonance frequency (PRF) shift and T-based thermometry methods. This work evaluates SR-VFA-SoS thermometry in MR-guided focused ultrasound in an in vivo rabbit model.
Methods: Simultaneous PRF shift thermometry and T-based thermometry were obtained in a New Zealand white rabbit model (n = 7) during MR-guided focused ultrasound surgery using the SR-VFA-SoS sequence at 3 T.
Biophys J
January 2025
Department of Chemistry and Biochemistry, University of Windsor, Windsor, Ontario, Canada. Electronic address:
α-Tocopherol (αtoc, vitamin E) is an essential nutrient sufficiently acquired through a balanced diet. This fat-soluble vitamin is most known for its antioxidative properties, however, its fundamental mechanism of action in cellular membranes remains unknown. To this end, we use time-resolved small angle neutron scattering (TR-SANS) and a contrast matching scheme to determine intervesicular exchange (k) and intrabilayer flip-flop (k) rates of αtoc in 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) vesicles.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!