Purpose: To evaluate the performance of swept source optical coherence tomography (SS-OCT) to detect gonioscopic angle closure using different classification algorithms.
Methods: This was a cross-sectional study of 2028 subjects without ophthalmic symptoms recruited from a community-based clinic. All subjects underwent gonioscopy and SS-OCT (Casia, Tomey Corporation, Nagoya, Japan) under dark room conditions. For each eye, 8 out of 128 frames (22.5° interval) were selected to measure anterior chamber parameters namely anterior chamber width, depth, area and volume (ACW, ACD, ACA, and ACV), lens vault (LV), iris curvature (IC), iris thickness (IT) from 750 µm and 2000 µm from the scleral spur, iris area and iris volume. Five diagnostic algorithms-stepwise logistic regression, random forest, multivariate adaptive regression splines, recursive partitioning and Naïve Bayes were evaluated for detection of gonioscopic angle closure (defined as ≥2 closed quadrants). The performance of the horizontal frame was compared with that of other meridians.
Results: Data from 1988 subjects, including 143 (7.2%) with gonioscopic angle closure, were available for analysis. They were divided into two groups: training (1391, 70%) and validation (597, 30%). The best algorithm for detecting gonioscopic angle closure was stepwise logistic regression with an area under the curve of 0.91 (95% CI 0.88 to 0.93) using all parameters, and 0.88 (95% CI 0.82 to 0.93) using only ACA, LV and IC of the horizontal meridian scan.
Conclusions: A stepwise logistic regression model incorporating SS-OCT measurements has a high diagnostic ability to detect gonioscopic angle closure.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1136/bjophthalmol-2021-319165 | DOI Listing |
J Clin Med
September 2024
Department of Ophthalmology, University of Muenster Medical Center, 48149 Muenster, Germany.
: Glaucoma, one leading cause of irreversible vision loss worldwide, is primarily caused by elevated intraocular pressure (IOP). Recently, minimally invasive glaucoma surgeries (MIGSs) have become popular due to their shorter surgical times, tissue-sparing nature, and faster recovery. One such MIGS, the Hydrus nickel-titanium alloy Microstent, helps lower IOP by improving aqueous humor outflow.
View Article and Find Full Text PDFInt J Ophthalmol
August 2024
VST Centre for Glaucoma Care, Kallam Anji Reddy Campus, L V Prasad Eye Institute, Hyderabad 500034, India.
Aim: To describe the gonioscopic profile and intraocular pressure (IOP) in primary angle-closure (PAC) disease in patients presenting to a tertiary eye care network in India.
Methods: A cross-sectional hospital-based study that included 31 484 new patients presenting between 2011 and 2021. Patients with a clinical diagnosis of PAC/suspect/glaucoma were included.
Ophthalmol Glaucoma
August 2024
Division of Ophthalmology Informatics and Data Science, Viterbi Family Department of Ophthalmology, Shiley Eye Institute, University of California, San Diego, La Jolla, California; Division of Biomedical Informatics, Department of Medicine, University of California San Diego, La Jolla, California; Hamilton Glaucoma Center, Viterbi Family Department of Ophthalmology, Shiley Eye Institute, University of California, San Diego, La Jolla, California. Electronic address:
Objective/purpose: Standardization of eye care data is important for clinical interoperability and research. We aimed to address gaps in the representations of glaucoma examination concepts within Systemized Nomenclature of Medicine - Clinical Terms (SNOMED-CT), the preferred terminology of the American Academy of Ophthalmology.
Design: Study of data elements.
J Glaucoma
November 2024
Ophthalmology Department, Norfolk and Norwich University Hospital.
Prcis: This survey highlights a deficiency in gonioscopy practices across the UK, particularly in the utilization of indentation gonioscopy and training of junior ophthalmologists. Recommendations include standardizing practice and enhancing training opportunities to improve patient care.
Objective: Gonioscopy is an important general skill learned and practiced by all grades of ophthalmologists.
Exp Eye Res
August 2024
Department of Ophthalmology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan. Electronic address:
Glaucoma is a neurodegenerative disease characterized by visual field loss associated with optic nerve damage and ocular hypertension. The biological basis for the elevated intraocular pressure (IOP) is largely unknown, such that lowering the IOP is currently the only established treatment. Several animal models have been developed to elucidate the mechanism underlying the increased IOP and for use in drug discovery research, but their utility is often limited by the occurrence of severe intraocular inflammation and by technical challenges.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!