Diseases of small diameter blood vessels encompass the largest portion of cardiovascular diseases, with over 4.2 million people undergoing autologous vascular grafting every year. However, approximately one third of patients are ineligible for autologous vascular grafting due to lack of suitable donor vasculature. Acellular extracellular matrix (ECM) scaffolds derived from xenogeneic vascular tissue have potential to serve as ideal biomaterials for production of off-the-shelf vascular grafts capable of eliminating the need for autologous vessel harvest. A modified antigen removal (AR) tissue process, employing aminosulfabetaine-16 (ASB-16) was used to create off-the-shelf small diameter (< 3 mm) vascular graft from bovine saphenous vein ECM scaffolds with significantly reduced antigenic content, while retaining native vascular ECM protein structure and function. Elimination of native tissue antigen content conferred graft-specific adaptive immune avoidance, while retention of native ECM protein macromolecular structure resulted in pro-regenerative cellular infiltration, ECM turnover and innate immune self-recognition in a rabbit subpannicular model. Finally, retention of the delicate vascular basement membrane protein integrity conferred endothelial cell repopulation and 100% patency rate in a rabbit jugular interposition model, comparable only to Autograft implants. Alternatively, the lack of these important basement membrane proteins in otherwise identical scaffolds yielded a patency rate of only 20%. We conclude that acellular antigen removed bovine saphenous vein ECM scaffolds have potential to serve as ideal off-the-shelf small diameter vascular scaffolds with high in vivo patency rates due to their low antigen content, retained native tissue basement membrane integrity and preserved native ECM structure, composition and functional properties. STATEMENT OF SIGNIFICANCE: The use of autologous vessels for the treatment of small diameter vascular diseases is common practice. However, the use of autologous tissue poses significant complications due to tissue harvest and limited availability. Developing an alternative vessel for use for the treatment of small diameter vessel diseases can potentially increase the success rate of autologous vascular grafting by eliminating complications related to the use of autologous vessel and increased availability. This manuscript demonstrates the potential of non-antigenic extracellular matrix (ECM) scaffolds derived from xenogeneic vascular tissue as off-the-shelf vascular grafts for the treatment of small diameter vascular diseases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8542604PMC
http://dx.doi.org/10.1016/j.actbio.2021.06.034DOI Listing

Publication Analysis

Top Keywords

small diameter
24
ecm scaffolds
16
vascular
13
bovine saphenous
12
saphenous vein
12
extracellular matrix
12
autologous vascular
12
vascular grafting
12
basement membrane
12
diameter vascular
12

Similar Publications

Cystic Basal Cell Carcinoma with a Giant Vulvar Cyst.

Acta Dermatovenerol Croat

November 2024

Takayuki Suyama, MD, PhD, Department of Dermatology, Dokkyo Medical University Saitama Medical Center, 2-1-50 Minami-koshigaya, Koshigaya, Saitama, 343-8555, Japan; ORCID ID: 0000-0002-6986-411X.

Cystic basal cell carcinoma (BCC) is a rare subtype of BCC (1). Histologically, it is usually characterized by multiple small cysts without a clinical cystic appearance (2). Herein, we report an unusual case of cystic BCC with a large vulvar cyst.

View Article and Find Full Text PDF

This study investigates the occurrence of multiple parafoveal retinal detachments (RDs) in myopic traction maculopathy (MTM), emphasizing the atypical extrafoveal involvement compared to central foveal detachment commonly observed. Patient 1, a 46-year-old male, exhibited MTM with retinoschisis and four small subretinal fluid (SRF) pockets inferior to the fovea, accompanied by a hyperautofluorescent vitelliform deposit. Patient 2, a 43-year-old male, reported ring-shaped dim vision in the left eye, displaying MTM with six stable SRF pockets surrounding the fovea.

View Article and Find Full Text PDF

Bioinspired 1D Anisotropic Double-Spiral Metal Wires for Efficient Fog Harvesting.

Small

January 2025

Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, School of Materials Science and Engineering, Hubei University, Wuhan, 430062, P. R. China.

Innovative design strategies of fog harvesting devices (FHDs) demonstrate promising remedy for water crisis in arid areas. 1D FHDs ensure unimpeded wind circulation and can be manufactured more cost-effectively for extensive regions. Inspired by cactus thorns, desert beetles, and spider silk, two metal organic frameworks (MOFs) functionalized Cu wires with opposite wettability are double-twisted by a mechanical twisting machine, forming 1D double-spiral Cu wires with alternating superhydrophobic/superhydrophilic dual-MOF patterns.

View Article and Find Full Text PDF

The Effect of Aneurysm Diameter on Perioperative Outcomes Following Complex Endovascular Repair.

J Vasc Surg

January 2025

Divisions of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA. Electronic address:

Objectives: Endovascular aneurysm repair (EVAR) for large infrarenal abdominal aortic aneurysms (AAA) has been associated with worse outcomes compared to EVAR for smaller AAAs. Whether these findings apply to complex AAAs (cAAA) remains uncertain.

Methods: We identified all intact complex EVAR (cEVAR) from 2012-2024 in the Vascular Quality Initiative.

View Article and Find Full Text PDF

Mini Fragment and Small Fragment Screws are Comparable in Acute Syndesmotic Injury.

J Foot Ankle Surg

January 2025

Trauma Unit, Department of Surgery, Amsterdam UMC location University of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam, the Netherlands. Electronic address:

Ankle fractures are often accompanied by syndesmotic injuries, contributing to instability and potential long term complications. Syndesmotic injuries are traditionally fixed with either small fragment (3.5-mm diameter) or large fragment (4.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!