An increasing number of Nuclear Medicine sites in Europe are using cardiac-centered gamma cameras for myocardial perfusion scintigraphy (MPS). Three cardiac-centered gamma cameras are currently the most frequently used in Europe: the D-SPECT (Spectrum Dynamics), the Alcyone (Discovery NM 530c and Discovery NM/CT 570c; General Electric Medical Systems), and the IQ-SPECT (Siemens Healthcare). The increased myocardial count sensitivity of these three cardiac-centered systems has allowed for a decrease in the activities of radiopharmaceuticals injected to patients for myocardial perfusion imaging and, consequently, radiation exposure of patients. When setting up protocols for MPS, the overall objective should be to maintain high diagnostic accuracy of MPS, while injecting the lowest activities reasonably achievable to reduce the level of radiation exposure of patient and staff. These guidelines aim at providing recommendations for acquisition protocols and image interpretation using cardiac-centered cameras. As each imaging system has specific design and features for image acquisition and analysis, these guidelines have been separated into three sections for each gamma camera system. These recommendations have been written by the members of the Cardiovascular Committee of EANM and were based on their own experience with each of these systems and on the existing literature.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8218102PMC
http://dx.doi.org/10.1186/s41824-019-0058-2DOI Listing

Publication Analysis

Top Keywords

myocardial perfusion
12
cardiac-centered gamma
12
gamma cameras
12
perfusion scintigraphy
8
three cardiac-centered
8
radiation exposure
8
cardiac-centered
5
eanm procedural
4
procedural guidelines
4
myocardial
4

Similar Publications

TLR4 Inhibition Attenuated LPS-Induced Proinflammatory Signaling and Cytokine Release in Mouse Hearts and Cardiomyocytes.

Immun Inflamm Dis

January 2025

Division of Physiology, Department of Molecular Medicine, Institute of Basic Medical Sciences, University of Oslo, Oslo, Norway.

Background: Sepsis is associated with myocardial injury and early mortality. The innate immune receptor Toll-like receptor 4 (TLR4) can recognize pathogen-associated-molecular-patterns (PAMPs) and damage-associated molecular patterns (DAMPs); the latter are released during tissue injury. We hypothesized that TLR4 inhibition reduces proinflammatory signaling and cytokine release in: (1) LPS or Escherichia coli-treated isolated mouse heart; (2) LPS-treated mouse primary adult cardiomyocytes; and (3) the isolated heart during ischemia-reperfusion.

View Article and Find Full Text PDF

Refractory angina pectoris (RAP) is a clinical syndrome characterized by persistent chest pain caused by myocardial ischemia that is unresponsive to optimal pharmacological therapy and revascularization procedures. Spinal cord stimulation (SCS) has emerged as a promising therapeutic option for managing RAP, offering significant symptom relief and improved quality of life. A systematic literature review was conducted to evaluate the clinical effectiveness, mechanisms of action, and safety profile of SCS in treating RAP.

View Article and Find Full Text PDF

Myocardial ischemia-reperfusion injury increases myocardial microvascular permeability, leading to enhanced microvascular filtration and interstitial fluid accumulation that is associated with greater microvascular obstruction and inadequate myocardial perfusion. A burst of reactive oxygen species and inflammatory mediators during reperfusion causes myosin light chain kinase (MLCK)-dependent endothelial hyperpermeability, which is considered a preventable cause of reperfusion injury. In the present study, a single intravenous injection of MLCK peptide inhibitor PIK7 (2.

View Article and Find Full Text PDF

Objectives: Cardiac resynchronization therapy (CRT) is an intervention for heart failure patients with reduced ejection fraction who exhibit specific electrocardiographic indicators of electrical dyssynchrony. However, electrical dyssynchrony does not universally correspond to left ventricular mechanical dyssynchrony (LVMD). Gated single-photon emission computed tomography (SPECT) myocardial perfusion allows for the assessment of LVMD, yet its role in the CRT selection process remains debated.

View Article and Find Full Text PDF

Objective: To examine the role of noninvasive testing (NIT) before invasive coronary angiography (ICA) by evaluating the association between a positive myocardial perfusion imaging (MPI) or computed tomography angiography (CTA) result and the decision to perform coronary revascularization.

Patients And Methods: We screened all patients who received ICA between August 1, 2015, and July 31, 2019, and identified those who received MPI or CTA within the preceding 12 months. We considered MPI to be a positive result if it found moderate or severe ischemia in a specific coronary territory and CTA to be a positive result if it identified a stenosis greater than 50% in any major coronary artery.

View Article and Find Full Text PDF