Introduction: The objectives of the present study were to determine whether simvastatin (SIM) could reverse the harmful effects on titanium rod osseointegration in ovariectomized rats fed high-fat diet (HFD).
Materials And Methods: Ovariectomized female Sprague-Dawley rats were randomly allocated to three groups and received SIM treatment plus HFD for 12 weeks. We then evaluated the microstructure parameters, histological parameters, biomechanical parameters, bone turnover, and blood lipid level.
Results: After 12 weeks of treatment, SIM can significantly improve bone formation around the titanium rod and osseointegration including higher values of maximum push-out force, bone area ratio (BAR), bone-to-implant contact (BIC), bone mineral density (BMD), bone volume (BV/TV), trabecular number (Tb.N), trabecular thickness (Tb.Th), mean connective density (Conn.D) when compared with the HFD group. In addition, system administration of SIM showed positive effects on collagen type 1 cross-linked C-telopeptide (CTX-1), procollagen I N-terminal propeptide (PINP), total cholesterol (TC), triglycerides (TGL), low-density lipoprotein (LDL) cholesterol and high-density lipoprotein (HDL) cholesterol. Compared with the HFD group, lower values of CTX-1, P1NP, TC, TGL and LDL were observed in the SIM+HFD group (P < 0.05).
Conclusion: Our findings revealed that HFD may have an adverse effect on osseointegration in osteoporotic conditions, and the harmful effect of HFD on osseointegration could be reversed by SIM.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00774-021-01243-0 | DOI Listing |
Acta Bioeng Biomech
September 2024
Department of Mechanics, Materials and Biomedical Engineering, Faculty of Mechanical Engineering, Wrocław University of Science and Technology, Wrocław, Poland.
: The aim of this study was to evaluate the abrasive wear of the sliding screw-rod joint used in growth guidance system (GGS) stabilizers, allowing for the translation of the screw along the rod during the spinal growth process in a standard and modified system. : The study used single kinematic screw-rod pairs made of titanium alloy Ti6Al4V. Mechanical tests (cyclic loads) simulated the stabilizer's operation under conditions similar to actual use.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Orthopedic Surgery, Anam Hospital, Korea University College of Medicine, 73 Goryeodae-ro Seongbuk-gu, Seoul 02841, Republic of Korea.
Distal tibia fractures are high-energy injuries characterized by a mismatch between standard plate designs and the patient's specific anatomical bone structure, which can lead to severe soft tissue damage. Recent advancements have focused on the development of customized metal plates using three-dimensional (3D) printing technology. However, 3D-printed metal plates using titanium alloys have not incorporated a locking system due to the brittleness of these alloys.
View Article and Find Full Text PDFFront Bioeng Biotechnol
January 2025
Department of Orthopedics, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China.
Background: Currently, some novel rods with lower elastic modulus have the potential as alternatives to traditional titanium alloy rods in lumbar fusion. However, how the elastic modulus of the rod (rod-E) influences the biomechanical performance of lumbar interbody fusion remains unclear. This study aimed to explore the quantitative relationships between rod-E and the biomechanical performance of transforaminal lumbar interbody fusion (TLIF).
View Article and Find Full Text PDFUltrason Sonochem
January 2025
State Key Laboratory of Precision Manufacturing for Extreme Service Performance, Central South University, Changsha 410083, China; Light Alloy Research Institute, Central South University, Changsha 410083, China.
The chemical corrosion of the TC4 radiation rod surface (TRRS) during the ultrasonic casting process has the potential to significantly impair the smooth conduction of ultrasonic waves. However, in the later stages of corrosion, a self-protected structure (TSPS) emerges under the ultrasonic cavitation effect, which serves to impede the chemical corrosion of the TRRS and markedly reduce the rate of mass loss of the radiation rod. This ensures the smooth ultrasonic conduction of the radiation rod during operation.
View Article and Find Full Text PDFJ Clin Med
December 2024
Spine Surgery Unit, IRCSS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy.
Severe early-onset scoliosis (EOS) can be addressed by different growth-friendly approaches, although the indications of each technique remain controversial. The aim of this study was to compare, in a large series of patients, the potential and limitations of the different distraction-based surgical techniques to establish the most suitable surgical approach to treat EOS. We conducted a retrospective observational cohort study evaluating 62 EOS cases treated between January 2002 and December 2021 with a traditional growing rod (TGR), a magnetically controlled growing rod (MCGR) and vertical expandable prosthesis titanium ribs (VEPTR) at IRCSS Istituto Ortopedico Rizzoli, Bologna, Italy.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!