A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reproducibility of the Rotor 2INpower Crankset for Monitoring Cycling Power Output: A Comprehensive Analysis in Different Real-Context Situations. | LitMetric

Purpose: To examine the reproducibility (intradevice and interdevice agreement) of the Rotor 2INpower device under a wide range of cycling conditions.

Methods: Twelve highly trained male cyclists and triathletes completed 5 cycling tests, including graded exercise tests at different cadences (70-100 rpm), workloads (100-650 W), pedaling positions (seated and standing), and vibration conditions (20-40 Hz) and an 8-second maximal sprint (>1000 W). An intradevice analysis included a comparison between the power output registered by 3 units of Rotor 2INpower, whereas the power output provided by each one of these units and the gold-standard SRM crankset were compared for the interdevice analysis. Among others, statistical calculations included the standard error of measurement, expressed in absolute (in watts) and relative terms as the coefficient of variation (CV).

Results: Except for the graded exercise test seated at 100 rpm/100 W (CV = 10.2%), the intradevice analysis showed an acceptable magnitude of error (CV ≤ 6.9%, standard error of measurement ≤ 12.3 W) between the 3 Rotor 2INpower. Similarly, these 3 units showed an acceptable agreement with the gold standard in all graded exercise test situations (CV ≤ 4.0%, standard error of measurement ≤ 13.1 W). On the other hand, both the intradevice and interdevice agreements proved to be slightly reduced under high cadences (intradevice: CV ≤ 10.2%; interdevice: CV ≤ 4.0%) and vibration (intradevice: CV ≤ 4.0%; interdevice: CV ≤ 3.6%), as well as during standing pedaling (intradevice: CV ≤ 4.1%; interdevice: CV ≤ 2.5%). Although within the limits of an acceptable agreement, measurement errors increased during the sprint tests (CV ≤ 7.4%).

Conclusions: Based on these results, the Rotor 2INpower could be considered a reproducible tool to monitor power output in most cycling situations.

Download full-text PDF

Source
http://dx.doi.org/10.1123/ijspp.2021-0137DOI Listing

Publication Analysis

Top Keywords

rotor 2inpower
20
power output
16
graded exercise
12
standard error
12
error measurement
12
≤ 40%
12
intradevice ≤
12
interdevice ≤
12
11
intradevice interdevice
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!