Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Contralateral C7 (CC7) nerve transfer has successfully restored hand function in patients with spastic hemiplegia from chronic central nervous system injuries. However, little is known about the morphology and anatomy of the donor C7 nerve root in patients undergoing this procedure. This study quantified intraoperative measurements of donor C7 nerve roots during CC7 transfer surgery for spastic hemiplegia in patients treated at a high-volume center to describe observed anatomical variations for successful direct anastomosis.
Methods: A database of images from 21 patients (2 females, 19 males) undergoing CC7 surgery was searched for photographic data that contained a standard ruler measuring donor C7 nerve root length after surgical sectioning and before transfer. Two independent observers analyzed these images and recorded C7 nerve root diameter, length, and branch lengths.
Results: Mean (SD) values of donor C7 nerve measurements were length, 53.5 (8.0) mm; diameter, 5.1 (0.9) mm; branch length following surgical sectioning, 18.3 (6.3) mm. Right-sided donor C7 nerve roots yielded significantly longer branches compared with left-sided donor C7 nerve roots (P = 0.01). Other patient factors such as age, sex, or laterality of brain injury did not influence intraoperative anatomy.
Conclusions: We report detailed intraoperative measurements of the donor C7 root during CC7 nerve transfer for spastic hemiplegia. These findings describe existing variation in surgical C7 nerve root anatomy in patients undergoing this procedure and may serve as a general reference for the expected donor C7 length in successful direct anastomosis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.wneu.2021.06.087 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!