Purpose The aim of this study was to evaluate the stability of single crowns and 3-unit bridges in relation to the implant-abutment complex with and without tube in tube connection.Methods 60 specimens with a total of 90 implants (diameter 3.8 mm) were fabricated and distributed into 4 groups: CST (Crown with short tube), CLT (crown with long tube), BNT (Bridge without tube) and BLT (bridge with long tube). All superstructures consisted of one-piece hybrid abutment restorations out of monolithic zirconia, bonded on prefabricated titanium bases and were directly screwed into the implants. Specimen underwent artificial aging (2.000.000 cycles, 120 N, 30° off axis) and were subsequently loaded in an universal testing machine at an angle of 30° until failure. The specimens were examined for damage during and after artificial aging.Results During artificial aging, one test specimen of group CLT and two test specimens of group BNT failed. The average failure load was 498.8 (± 34.4) N for CLT, 418.8 (± 41.5) N for CST, 933.1 (± 26.2) N for BLT and 634.4 (± 29.0) N for BNT, with a statistical differences (p ˂ 0.001) between the crown and bridge groups. All tested samples exhibited macroscopic deformations at the implant shoulder, which were more pronounced in the specimens without a tube in tube connection.Conclusions Single crowns and 3-unit bridges with a long tube in tube connection showed significantly higher fatigue fracture strength compared to restorations with short or without tube in tube connection.

Download full-text PDF

Source
http://dx.doi.org/10.2186/jpr.JPR_D_20_00036DOI Listing

Publication Analysis

Top Keywords

tube tube
16
single crowns
12
crowns 3-unit
12
3-unit bridges
12
tube
12
long tube
12
stability single
8
short tube
8
artificial aging
8
tube connection
8

Similar Publications

Background: Surgical site infection (SSI) is a significant complication following pediatric cardiovascular surgery. Although drain tip cultures (DTC) are sometimes used postoperatively to predict SSIs, their diagnostic value in pediatric cardiovascular surgery remains unclear. This study aimed to assess the diagnostic utility of DTC for predicting SSIs in pediatric cardiovascular surgery patients.

View Article and Find Full Text PDF

Animals can use specific environmental cues to make informed decisions about whether and where to disperse. Patch conditions are known to affect the dispersal behavior of animals, but empirical studies investigating the impact of resource diversity on the dispersal of closely related species are largely lacking. In this study, we investigated how food diversity affects the dispersal behavior of three co-occurring cryptic species of the marine bacterivorous nematode complex (Pm I, Pm III and Pm IV).

View Article and Find Full Text PDF

The characterization of in regulation of flower size through tuning cell expansion genes.

Front Plant Sci

December 2024

Zhejiang Provincial Key Laboratory of Germplasm Innovation and Utilization for Garden Plants, School of Landscape and Architecture, Zhejiang A&F University, Hangzhou, Zhejiang, China.

Flower appearance stands as a key characteristic of flowering plants and is closely linked to their ornamental value. Phytohormone Gibberellin (GA), essential for plant growth and development are widely reported for expansion in flower. DELLA proteins are known to negatively regulate GA signaling and influences plant growth and development through the regulation of cell expansion.

View Article and Find Full Text PDF

Karl Landsteiner discovered ABO blood group system in the early 20 century, but still, uncertainty remains in immunohematology while detection of ABO subgroups or weaker variants. The presence of weak subgroups in patient samples gives rise to the discrepancy in forward (cell) and reverse (serum) grouping. We here report a case of the B(A) phenotype in a patient who was diagnosed with chronic liver disease with acute pancreatitis, requiring packed red blood cells due to anemia.

View Article and Find Full Text PDF

Introduction: Weak D red cells were defined as having a reduced amount of D antigen (formerly called "Du") that required an indirect antiglobulin test (IAT) for detection. Weakly reacting D is those which give <2+ reactions on routine methods. The present study is sharing our experience on weak D and weakly positive anti-D in various methods.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!